8.14
Section 8
Electrical System and Components
Rectified Only (Non-Regulated) Systems
Some engines are equipped with a 3 or 18 amp
rectified, non-regulated charging system. The rectifier
is connected to the engine with a matching wiring
harness. Grounded through the wiring harness, the
rectifier module is secured to the equipment with a
single mounting screw. The rectifier converts the AC
voltage coming from the stator to DC voltage only. The
3 amp rectifier is shown in Figure 8-18.
Figure 8-18. 3 Amp Rectifier.
Figure 8-19. Connections for Testing Charging Systems.
Plug in
Connector
Rectifier-Regulator
(–)
(+)
Ground
Lead (Black)
Stator ‘‘AC’’ Leads (White)
Connect Tester Leads to Female
Bullet Connector (Red Wire)
Battery
Ammeter
DC Voltmeter