4.3
Section 4
Air Intake and Air Cleaner System
4
Figure 4-9. Removing Heavy-Duty Lower Chamber.
Figure 4-10.
Figure 4-11. Installing Heavy-Duty Cover/Housing.
Paper Element Service
Every 100 hours of operation (more often under
extremely dusty or dirty conditions), check the paper
element. Replace the element as necessary. Follow
these steps:
1. Standard Air Cleaner:
Loosen the air cleaner cover knob and remove
the cover. Remove the wing nut and lift off the air
cleaner element with precleaner. Remove the
precleaner from the paper element. Service the
precleaner.
Heavy-Duty, Cyclonic Air Cleaner:
Unhook the latches and remove the housing
assembly from the mounting base. Remove the
wing nut (some models) securing air cleaner/
precleaner assembly, or pull the complete filter
assembly out of the housing. Remove the
precleaner from the paper element. Service the
precleaner.
2. Do not wash the paper element or use
pressurized air, as this will damage the element.
Replace a dirty, bent, or damaged element with a
genuine Kohler element. Handle new elements
carefully; do not use if the sealing surfaces are
bent or damaged.
Figure 4-8. Removing Heavy-Duty Precleaner.
Содержание COMMAND PRO CS10
Страница 1: ...SERVICE MANUAL COMMAND PRO CS SERIES 4 12 HP HORIZONTAL CRANKSHAFT...
Страница 20: ...1 18 Section 1 Safety and General Information...
Страница 24: ...2 4 Section 2 Special Tools...
Страница 48: ...6 4 Section 6 Lubrication System...
Страница 54: ...7 6 Section 7 Retractable Starter...
Страница 84: ...8 30 Section 8 Electrical System and Components...
Страница 106: ...9 22 Section 9 Disassembly...
Страница 122: ...10 16 Section 10 Internal Components...
Страница 154: ...ENGINE DIVISION KOHLER CO KOHLER WISCONSIN 53044 LITHO IN U S A FORMNO TP 2503 A ISSUED 12 99 REVISED 8 00 MAILED 9 00...