![Kohler COM7.5 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/kohler/com7-5/com7-5_service-manual_1989803008.webp)
TP-6120 5/02
IV
Safety Precautions and Instructions
Moving Parts
Rotating parts.
Can cause severe injury or death.
Operate the generator set only when
all guards, screens, and covers are in
place.
WARNING
Tightening the hardware.
Flying
projectiles can cause severe injury
or death.
Loose hardware can cause
the hardware or pulley to release from
the generator set engine and can cause
personal
injury.
Retorque
all
crankshaft and rotor hardware after
servicing. Do not loosen the crankshaft
hardware or rotor thrubolt when making
adjustments or servicing the generator
set. Rotate the crankshaft manually in
a clockwise direction only. Turning the
crankshaft
bolt
or
rotor
thrubolt
counterclockwise
can
loosen
the
hardware.
Notice
NOTICE
Hardware damage.
The engine and
generator set may use both American
Standard and metric hardware. Use
the correct size tools to prevent
rounding of the bolt heads and nuts.
NOTICE
When replacing hardware, do not
substitute
with
inferior
grade
hardware.
Screws and nuts are
available in different hardness ratings.
To
indicate
hardness,
American
Standard hardware uses a series of
markings, and metric hardware uses a
numeric system. Check the markings
on the bolt heads and nuts for
identification.
NOTICE
Electrostatic
discharge
damage.
Electrostatic
discharge
(ESD)
damages electronic circuit boards.
Prevent
electrostatic
discharge
damage by wearing an approved
grounding wrist strap when handling
electronic circuit boards or integrated
circuits. An approved grounding wrist
strap provides a high resistance (about
1 megohm),
not a direct short
, to
ground
.
NOTICE
Fuse replacement.
Replace fuses
with fuses of the same ampere rating
and type (for example: 3AB or 314,
ceramic).
Do not substitute clear
glass-type fuses for ceramic fuses.
Refer to the wiring diagram when the
ampere
rating
is
unknown
or
questionable.
Содержание COM7.5
Страница 1: ...Commercial Generator Sets Models COM7 5 TP 6120 5 02 Service ...
Страница 14: ...TP 6120 5 02 4 Section 1 Specifications Notes ...
Страница 22: ...TP 6120 5 02 12 Section 2 Scheduled Maintenance Notes ...
Страница 32: ...TP 6120 5 02 22 Section 3 General Troubleshooting Notes ...
Страница 52: ...TP 6120 5 02 42 Section 7 Wiring Diagrams Figure 7 1 Wiring Diagram GM20551 ...
Страница 53: ...TP 6120 5 02 43 Section 7 Wiring Diagrams Figure 7 2 Schematic ADV 6654 ...
Страница 54: ...TP 6120 5 02 44 Section 7 Wiring Diagrams Notes ...
Страница 60: ......
Страница 61: ......
Страница 62: ......
Страница 63: ......