Electrical System
66 690 14 Rev. A
KohlerEngines.com
3. With engine stopped, measure resistance across
stator leads using an ohmmeter.
Condition
Conclusion
Resistance is 0.1/0.2
ohms.
Stator is OK.
Resistance is 0 ohms.
Stator is shorted; replace.
Resistance is in
fi
nity
ohms.
Stator is open; replace.
4. With engine stopped, measure resistance from each
stator lead to ground using an ohmmeter.
Condition
Conclusion
Resistance is in
fi
nity ohms
(no continuity).
Stator is OK (not shorted
to ground).
Resistance (or continuity)
measured.
Stator leads are shorted to
ground; replace.
Test Charging System for Battery Continuously
Charging at High Rate
1. With engine running at 3600 RPM, measure voltage
from B+ lead to ground using a DC voltmeter.
Condition
Conclusion
Voltage is 14.7 volts or
less.
Charging system is OK.
Battery is unable to hold
charge; service or replace.
Voltage is more than 14.7
volts.
Faulty recti
fi
er-regulator;
replace.
To Test 25 amp Recti
fi
er-Regulators
NOTE: When installing recti
fi
er-regulator, take note of
terminal markings and install plug(s) accordingly.
NOTE: Disconnect all electrical connections attached to
recti
fi
er-regulator. Testing may be performed
with recti
fi
er-regulator mounted or loose. Repeat
applicable test procedure two or three times to
determine condition of part.
NOTE: A
fl
ashing LOW light can also occur as a result
of an inadequate ground lead connection. Make
certain connection location is clean and clamp is
secure.
Testing recti
fi
er-regulator may be performed as follows,
using appropriate recti
fi
er-regulator tester.
1. Connect tester ground lead (with spring clamp) to
body of recti
fi
er-regulator.
2. Connect red lead from tester to middle terminal
labeled B+.
3. Connect black leads from tester to both outer AC
terminals on recti
fi
er-regulator.
4. Plug tester into proper AC outlet/power supply for
tester being used. Turn on power switch. POWER
light should be illuminated and one of four status
lights may be lit as well. This does not represent
condition of part.
5. Press TEST button until a click is heard and then
release. Momentarily one of four status lights will
illuminate indicating partial condition of part.
Condition
Conclusion
OK (green) light comes on
and stays steady.
Disconnect tester black
lead attached to 1 AC
terminal and reconnect
it to other AC terminal.
Repeat test. If OK (green)
light comes on again, part
is good and may be used.
NOTE: A
fl
ashing LOW
light can also
occur as a result
of an inadequate
ground lead
connection. Make
certain connection
location is clean
and clamp is
secure.
Other lights come on.
Recti
fi
er-regulator is faulty
and should not be used.