background image

Handling instructions and precautions

Mounting and piping

Sensor head and connector connection overview

The

 ZLS1-

 sensor head is provided with the mini clamp wire mount 

plug connected to the sensor head unit.  A special tool is required if you 
need  to  reconnect  in  order  to  adjust  the  length.    Use  the  following 
procedure when reconnecting.

1.  Be  sure  to  use  the  mount  plug  and  the  special  tool  shown  below 

when reconnecting.

  6 P mini clamp wire mount plug   Model: 

ZL-6M

  Special tool 

Model: 

1729940-1

   

Tyco Electronics Japan G.K.

2.  Check  to  make  sure  that  the  connector  cover  (lead  wire  inlet)  is 

raised  above  the  body  of  the  connector.    Note  that  a  connector 
whose cover is even with the body of the connector cannot be used.

3. Cut the sensor head cable to the required length.
   Strip the outer covering of the cable, 50 mm [1.969 in] from the end, 

to  expose  the  lead  wires.    Do  not  strip  the  insulation  from  the 
individual lead wires at this time.

50 mm [1.969 in]

4. Insert the lead wires into the connector cover holes in accordance with 

the information in the table below.  Check to make sure the lead wires 
are fully inserted (wire goes in about 9 mm [0.354 in]) as far as they 
will go by looking into the semi-transparent top cover of the connector.

   Note  that  supplying  power  while  connections  are  incorrect  will 

damage the sensor head and controller.

Number on connector

Signal name

Lead wire color

1

Sensor head voltage (+)

Sensor head brown lead

2

Sensor head voltage output A_IN

Sensor head white lead

3

Sensor head voltage output B_IN

Sensor head black lead

4

Indicator (LED) input

Sensor head red lead

5

GND

Sensor head blue lead

6

NC

Unconnected

5. Taking care not to allow the lead wires to come out of the connector, 

use the special tool to squeeze the cover and body of the connector 
until the cover is pressed into the body.

  Connection is complete when the cover is even with the connector body.

6.  Double check to make sure that wiring is correct.

Attaching and detaching of the sensor head and power supply/switching cables

To  attach  the  sensor  head  and  the  power  supply/switching  cables, 
position  the  lock  levers  as  shown  in  the  illustration  above,  and  then 
insert until they lock into place with the controller side connectors.  To 
disconnect, press the lock lever down as far as it will go as you pull the 
connector to unplug it.  At this time, take care not to apply undue force 
to the lead wires.

Attaching the protective front cover

Attach the protective front cover so the tabs inside the cover enter the 
slots on the Linear Magnetic Sensor Controller.

*  To remove the protective front cover, hook your finger on the projection 

on one side of the cover and remove it.

Sensor head installation precautions

1.  Insert  the  sensor  head  into  the  switch  mounting  groove  of  the  air 

hand or cylinder to be used.  Tighten to a torque of less than 0.2 N

[1.77 in

lbf].

2.  For  information  of  the  sensor  head  insertion  direction,  refer  to  the 

"Sensor switch mounting" for the air hand or cylinder you are using.

Unconnected

654321

Sensor head

Red

Black White

Brown

Unconnected

654

321

Sensor head

Blue

1

2

3

4

ZL1

KOGANEI

SW.OUT

6

5

4

3

2

1

Brown

White

Black

Red

Blue

Gap

Lock lever

Lock lever

8

7

6

5

4

3

2

1

Power supply/switching cable

ZLW-3L

Sensor head
ZLS1-

Protective front cover (available separately)
ZLBK100

Slot

tab

Protrusion

2

駆動機器図面

エアシリンダ

三校

848

旧版

5

03̲2016

Содержание ZL1 Series

Страница 1: ... of inner circuits 849 Specifications 850 Order codes 851 Dimensions 852 Setting instructions 854 Before use be sure to read the safety precautions at the front of the general personal catalog CAUTION Linear Magnetic Sensor Controller RoHS directive compliant products 845 03 2016 ...

Страница 2: ... display 100 60 40 0F Responsedifferential fixed t Hand full open Holding workpiece Hand full open Hand full open Responsedifferential fixed Effective setting range signal STABI The ON range of each output can be set within the effective measuring range sensor head ON range Response differential is fixed 2 F S When the controller setting and sensor heat setting positions are as shown below OUT1 Th...

Страница 3: ...0 197 5 0 197 L hand NHL1D 4 0 157 4 0 157 5 0 197 5 0 197 5 0 197 Air hand NHB parallel type NHB PG L 4 0 157 6 5 0 256 10 0 394 14 0 551 20 0 787 Air hand NHB parallel type NHB P A 4 0 157 4 0 157 8 0 315 12 0 472 14 0 551 Air hand NHB swing type NHB S 10 to 30 10 to 30 10 to 30 10 to 30 10 to 30 NHB swing 180 degrees NHBDSL G 80 85 65 65 Flat type air hand AFDPG 5 0 197 9 0 354 7 0 276 10 0 394...

Страница 4: ...D input Sensor head red lead 5 GND Sensor head blue lead 6 NC Unconnected 5 Taking care not to allow the lead wires to come out of the connector use the special tool to squeeze the cover and body of the connector until the cover is pressed into the body Connection is complete when the cover is even with the connector body 6 Double check to make sure that wiring is correct Attaching and detaching o...

Страница 5: ... transitional state 1 second when the power is turned on 3 Never use a needle or any other sharp pointed object to perform key operations 24 VDC 10 D Main circuit Linear magnetic sensor controller Sensor head Power supply switching cable Note If you use an extended cable be aware that voltage decreases due to its resistance 1 2 3 4 5 OV blue wire LED red wire B_IN black wire A_IN white wire V brow...

Страница 6: ... Hz Ambient temperature 0 to 50 C 32 to 122 F non condensation non freezing Storage temperature range 10 to 70 C 14 to 158 F non condensation non freezing Mass 20 g 0 705 oz when 1 L lead wire length is 1000 mm 39 in Controller Item Model ZL1 Power supply voltage 24 VDC 10 Consumption current 50 mA max not including supply power to sensor Sensor input supply power and voltage 5 VDC Sensor input ma...

Страница 7: ...ngth 1L 1000 mm 39 in 2L 2000 mm 79 in 3L 3000 mm 118 in Sensor head ZLW 3L Power supply switching cable ZLBK100 Protective front cover ZL 6M Mini clamp wire mount plug 6 P for sensor head ZL 8M Mini clamp wire mount plug 8 P for power supply switching cable Power supply switching cable Blank No power supply switching cable 3L With power supply switching cable length of 3000 mm 118 in 851 03 2016 ...

Страница 8: ...3 1 693 51 2 008 39 4 1 551 1 2 3 4 45 1 772 1 5 0 059 9 5 0 374 30 1 181 ZL1 KOGANEI SW OUT ZL1 KOGANEI SW OUT ZL1 JAPAN 752 6P_CON 5V A_IN B_IN LED GND NC 8P_CON P 1 2 3 4 5 6 7 8 P 1 2 3 4 5 6 24 VDC ANALOG STABI GND OUT_1 OUT_2 OUT_3 OUT_4 20 1 0 791 4 6 0 181 4 1 0 161 φ2 9 0 114 15 6 0 614 22 5 0 886 M2 5 slotted head set screw Center point of sensitivity of the sensor 7 2 0 283 Indicator li...

Страница 9: ...protective front cover ZL 6M mini clamp wire mount plug 6 P for sensor head ZL 8M mini clamp wire mount plug 8 P for power supply switching cable Dimensions mm in 5 7 0 224 5 0 197 30 1 181 34 7 1 366 24 1 0 949 Red 18 5 0 728 6 0 236 5 03 0 198 15 6 0 614 853 03 2016 ...

Страница 10: ... flash memory Note that flash memory has a limited life and the number of rewrites is 10 000 Nomenclature and functions No Name Description Display Effective measuring range setting details error indicators Switch output indicator Lights when switch output is ON Channels 1 to 4 UP key Use to increase a setting value DOWN key Use to decrease a setting value Mode key Use when configuring settings t ...

Страница 11: ...el of mounted cylinder 10 Selects the output mode of each channel CO4 Can be used to invert the switch output of each channel S 0 Changes the sensor head LED indicator HI 60 LO 40 Configures the scaling setting OFS 0 FS 100 Configures the display panel setting bL 1 Configures the LCD display cycle dT 1 Adjusts the switch output response time of each channel Sd 1 Performs initialization 1 Performs ...

Страница 12: ...hanges the model number of the cylinder that is mounted 5 Returns to sensing mode after one second Use the procedure below to specify the output mode for each channel Note These settings are valid within the effective measuring range operation range Output mode setting SET3 Procedure Button operation Display after operation Remark 1 Set the output mode of each OUT 2 Select the channel of each OUT ...

Страница 13: ...Error description Error clear The selected channel s sensor head is burned out or not connected In case of burn out turn off power and then replace the sensor head I n v a l i d s e t t i n g w h e n configuring the scaling setting Reconfigure the scaling setting so it satisfies the required scaling conditions Overvoltage applied to sensor input After eliminating the cause of the error hold down t...

Страница 14: ...858 03 2016 ...

Отзывы: