Setting the backlight color
LCD display cycle setting
Switch output response time setting
Use the procedure below to set the backlight color.
Backlight display setting (SET7)
Procedure Button operation Display after operation
Remark
1
2
Backlight setting
3
to
4
Returns to detection mode after one second.
Backlight OFF
Switch output OFF: Green Switch output ON: Red
Switch output OFF: Red Switch output ON: Green
Always green
Always red
•
Connection to switch output is linked with switch output channel 1.
5 ms Max
≒
20 ms
≒
100 ms
≒
1000 ms
250 ms
500 ms
1000 ms
Use the procedure below to return settings to their initial defaults. At
the same time, you can also check the status of the display and output.
Use the procedure below to return settings to their initial defaults.
Use the procedure below to set the switch output response time.
Use the procedure below to configure the LCD display cycle setting.
Note: Performing the above operation causes all switch output to become ON
momentarily.
Also, all data is initialized after the above operation is performed. Make written
copies of any settings you have changed before performing the above operation.
Note: All data is initialized after the above operation is performed.
Keep a separate record of settings you have changed.
Initialization 2 (display, output check)
Initialization 1
Switch output response time setting (SET9)
LCD display cycle setting (SET8)
Error indications
Name
Error description
Error clear
T h e s e l e c t e d c h a n n e l's
sensor head is burned out or
not connected.
In case of burn out, turn off
power and then replace the
sensor head.
I n v a l i d s e t t i n g w h e n
configur ing the scaling
setting.
Reconfigure the scaling
setting so it satisfies the
required scaling conditions.
O ve r vo l t a g e a p p l i e d t o
sensor input.
After eliminating the cause
of the error, hold down the
mode key for at least one
second.
(n = applicable channel)
O ve r c u r r e n t f l o w i n g t o
switch output.
Use the procedure below to adjust the maximum output voltage of analog output.
Adjustment for the maximum output voltage of analog output (SETC)
Procedure Button operation Display after operation
Remark
1
Adjusts the maximum output voltage of analog output.
2
3
Voltage output by analog output.
4
Value change
Check the analog output voltage with a
multimeter or some other instrument and
adjust the maximum output voltage.
5
Returns to detection mode after one second.
Procedure Button operation Display after operation
Remark
1
Perform initialization. (Check display)
2
Press the 3 buttons at the same time.
While holding down [MODE], press
the following in sequence
→
.
Procedure Button operation Display after operation
Remark
1
Performs initialization.
2
Press the 3 buttons at the same time.
While holding down [MODE], press the
following in sequence:
→
.
Procedure Button operation Display after operation
Remark
1
2
Output delay setting
3
to
4
Returns to detection mode after one second.
Procedure Button operation Display after operation
Remark
1
2
Sampling cycle setting
3
to
4
Returns to detection mode after one second.
2