−0. 07 to 1. 0 MPa (gauge pressure)
−10 to
+
60℃ (non-freezing)
0 to 90% RH (Non-condensation)
−20 to
+
70℃ (non-freezing)
0 to 90% RH (Non-condensation)
1. 5 MPa (gauge pressure)
100
㎖
/h (normal) (when flow meter internal pressure is 1. 5 MPa)
24VDC
22. 8 to 25. 2VDC
120 mA max.
50±5 ms (when shipped)
Specifications
Model
Item
FAS-002
4 to 200
(
10 to 200
)
2
−60 to 400
1
10
−60 to 400
−3.6 to 24.0
−0.060 to 0.400
−4.7 to 31.0
10 to 500
(
25 to 500
)
5
−150 to 1000
1
10
−150 to 1000
−9.0 to 60.0
−0.150 to 1.000
−11.6 to 77.6
60 to 3000
(
150 to 3000
)
30
−900 to 6000
5
10
−900 to 6000
−54.0 to 360
−0.900 to 6.000
−70 to 465.5
120 to 6000
(
300 to 6000
)
60
−1800 to 12000
10
100
−1800 to 12000
−108.0 to 720.0
−1.800 to 12.000
−140.0 to 931.0
240 to 12000
(
600 to 12000
)
120
−3600 to 24000
10
100
−3600 to 24000
−220.0 to 1440.0
−3.600 to 24.000
−279.0 to 1862.0
FAS-005
FAS-030
FAS-060
FAS-120
Air, nitrogen
However, dry air that does not include any corrosive elements (chlorine, sulfur, acid, etc.),
and clean air that does not include dust or oil mist
( )
±3
%
FS ±1 digit (2 to 100% of FS flow rate, 5 to 100% in the case of installation attitudes 2 and 3)
Note 9
On the order of ±6
%
FS (−30 to 0% of FS flow rate)
On the order of ±10
%
RD (100 to 200% of FS flow rate)
Note 7
±1. 0
%
FS ±1digit (2 to 100% of FS flow rate)
On the order of ±2
%
FS (−30 to 0% of FS flow rate)
On the order of ±10
%
RD (100 to 200% of FS flow rate)
Note 7
No more than 0. 15% FS/℃ ±1 digit
No more than −0. 25% FS/0. 1 MPa ±1 digit (2 to 40% of FS flow rate)
No more than −0. 55% FS/0. 1 MPa ±1 digit (40 to 100% of FS flow rate)
No more than 0. 5% FS/0. 1 MPa±1 digit (5 to 100% of FS flow rate)
No more than 0. 5% FS/0. 01 MPa ±1 digit (5 to 100% of FS flow rate)
No more than −0. 5% FS/0. 1 MPa ±1 digit (5 to 100% of FS flow)
No more than −0. 5% FS/0. 01 MPa ±1 digit (5 to 100% of FS flow)
1 current output: 4 to 20 mA (Output range: 3. 2 to 20. 8 mA)
Fixed output during alarm (up): 21. 6 ±0. 4 mA (initial default, modifiable by setting)
Fixed output during alarm (down): 0. 0 ±0. 4 mA fixed
Allowable load resistance: 300 Ωmax.
Maximum output current: 24 mA max.
Within 1. 5 s (For 0
→
100
%
FS step input, time to reach 95% of maximum value, Calculation cycle: 50 ms)
Rc 1/4
Rc 1/2
Rc1
Rc1 1/2
Rc2
1 open collector output: 30VDC, 50 mA max.
One of the following functions can be selected.
・
Instantaneous flow rate upper limit, lower limit, range
・
Integrated flow rate countup, countdown
・
Alarm generation
・
Integrated pulse output (selection of three pulse weights)
Medium
Port size
Measurement flow rate range
Note 6
ℓ
/min (normal)
Minimum sensitivity
ℓ
/min (normal)
Maximum flow rate range
ℓ
/min (normal)
Display resolution
Note 5
Instantaneous flow rate
ℓ
/min (normal) Integrated flow rate
ℓ
/min (normal)
Maximum display range
m
3
/h (normal)
m
3
/min (normal)
㎏
/h
Instantaneous flow rate display accuracy
Instantaneous flow rate display repeatability
Temperature characteristics
Operating pressure
Pressure characteristics
0 to 1MPa
Operating pressure
−0. 07 to 0 MPa
Instantaneous flow rate
Operating pressure
display Change amount
Note 8
0 to 1MPa
at installation attitude 2
Operating pressure
−0. 07 to 0 MPa
Instantaneous flow rate
Operating pressure
display Change amount
Note 8
0 to 1 MPa
at installation attitude 3
Operating pressure
−0. 07 to 0 MPa
Operating pressure range
Operating temperature range
Operating humidity range
Storage temperature range
Storage humidity range
Proof pressure
External leakage amount
Rated voltage
Power supply voltage range
Consumption current
Calculation cycle
Instantaneous flow rate output
Note 10
Response time
Switch output
Note 11
No more than ±0. 25% FS/0. 01 MPa±1 digit (2 to 40% of FS flow rate)
No more than ±0. 55% FS/0. 01 MPa ±1 digit (40 to 100% of FS flow rate)