13 -
Select item to print out program of selected
analyzer. To change form, go to Config then
ProgramForm.
Sample Print Out
Program
Diesel
Sample Diesel
Sample ID
12.9.00
Operator Koehler
Comment
Sample
Program
Method
ASTM D86
Distillation Group
SG4
Condenser temp.
40.0°C
Receiver temp.
30.0°C
Expected volume
98.0 mL
Preheat 1
29.1%
Preheat time
3.0 min
Preheat 2
28.2%
Extended
Fix-temps.
Plate hole
50 mm
Fixtemp. 1
170.00 °C
Flask type
125 mL
Fixtemp. 2
180.00 °C
Distill. Rate
4.5 mL
Fixtemp. 3
190.00 °C
Final heat adj.
100.0%
Fixtemp. 4
210.00 °C
Stop at volume
420.00°C
Fixtemp. 5
270.00 °C
Solvent off Time
0.7 sec
Solvent off Temp
0.0 °C
Corr. Temp
0.00 °C