50
Up/Down
→
ENT
→
Up/Down (Select ON)
→
ENT -----------------------Parallel cursor appears
(Select ///CSR)
µ
>
Up/Down (Select OFF)
→
ENT -----------------Parallel cursor non-appears
Note: Interval of ///CSR same as fixed range marker.
///CSR moves with EBL1.
5.5.1.9 Establishment of the indication of the RANGE RINGS (RINGS)
(1) Use the up-down cursor key to select RINGS from among the pull-down and display items, and
press the “ENT” key.(ON/OFF displayed beside the RINGS item)
(2) Use the up-down key to select ON or OFF and press the “ENT” key
Select ON
Range Rings ON
Select OFF
Range rings OFF
Up/Down
→
ENT
--
→
Up/Down (Select ON)
→
ENT ----------------- Range rings appears
(Select RINGS)
µ
>
Up/Down (Select OFF)
→
ENT ----------- Range rings non-appears
•
Number of range rings and range interval
•
Radome antenna (RA40C)
Range
0.125
•0.25
0.5
0.75
1.5
3
6
12
24
Number of Rings
2
2
2
3
6
6
6
6
6
Interval
0.062
5
0.125
0.25
0.25
0.25
0.5
1
2
4
Radome antenna (RA41C)
Range
0.125
0.25
0.5
0.75
1.5
3
6
12
24
36
Number of Rings
2
2
2
3
6
6
6
6
6
8
Interval
0.0625
0.125
0.25
0.25
0.25
0.5
1
2
4
4
Open antenna (RA42C)
Range
0.125
0.25
0.5
0.75
1.5
3
6
12
24
48
Number of Rings
2
2
2
3
6
6
6
6
6
8
Interval
0.0625
0.125
0.25
0.25
0.25
0.5
1
2
4
6
5.5.1.10 Variable range function ( VAR RNG )
Usually the range changes in steps as 0.5--0.75--1.5--3.0--....., but using this function will
enable a consecutive change such as 0.5--0.6--0.7--0.8--..... .
(1) Use the up-down cursor keys to select VAR RNG from among the pulled down and displayed
.75
.25
HU
.75
.25
HU
Range rings
Range
rings
OFF
Содержание RA40C
Страница 24: ...14 Horizontal line Line of sight θ Fig 3 2 Obtaining sufficient dip angle ...
Страница 48: ...38 The function can be changed at the KEY ASSIGNMENT function in the CUSTOM menu of the SETUP ...
Страница 69: ...73 ...
Страница 80: ...63 a PPI Screen All functions can be used on this screen D V T D Q T g t PPIScr een ...
Страница 93: ...52 ...