48
appears. (Once this is set, the "ON" state continues unless changes are made.)
Up/Down
→
ENT
→
Up/Down
→
ENT --------------------------------FL VRM2 is turned ON and
(Select FL VRM2)
(Select ON)
the small cross mark appears.
(b) Setting a reference point for measurement of the distance
Use the left-right and up-down cursor keys to place the small cross mark on one of the two
echoes whose distance will be measured, and press the "ENT" key.
Up/Down & Left/Right
→
--------------------------- ENT
Criterion of the reference point is set.
(Place the cross cursor on an echo)
(c) Measuring
Perform the operations in the above mentioned "Common operation for the MARK menu"
and "measuring the distance(VRM2)", and place the VRM2 on another echo.
VRM2 is displayed on the screen around the placed fixed cross cursor.
" 2 xx. xNM" which is displayed at the lower right will be the distance between the two
points.
Note: EBL2 and VRM2 are not follow to "ZOOM" and "OFF-C" function.
5.5.1.6 Measuring the angle between two points (FL EBL2)
(a) Preparation for the measurement
(1) Use the up-down cursor keys to select FL EBL2 from among the pull-down display items,
and press the "ENT" key.
(2) Use the up-down cursor keys to select ON from the ON/OFF display beside the FL EBL2
items, and press the "ENT" key. “SET START POINT” is displayed and a small cross mark
appears. (Once this is set, the "ON" state continues unless changes are made.)
Up/Down
→
ENT
→
Up/Down
→
ENT --------------------------------FL EBL2 is turned ON and
(Select FL EBL2)
(Select ON)
the small cross mark appears.
(b) Setting a reference point for measurement of the angle.
Use the left-right and up-down cursor keys to place the small cross mark on one of the two
echoes whose angle will be measured, and press the "ENT" key.
Up/Down & Left/Right
→
ENT --- Criterion of the reference point is set.
(Place the cross cursor on an echo)
.75
.25
HU
2•0.72NM
place the VRM2
on another
echo
SET START POINT
.75
.25
HU
measure the
distance between
two targets
small cross
mark
FL VRM2 indication
of VRM2
center of
VRM2
Содержание RA40C