Chapter 6 Troubleshooting and on-board repair
MDC-2200/2500 Series
6-2
0092625002-07
6.2.1.1 Error display list
Table 6.1 Error display list
Error location
Error status
Cause
Antenna
Not connected
Antenna connecting cable is disconnected.
Magnetron high voltage
TXHV fuse blown, Transmitter PCB malfunction
Magnetron current
TXHV fuse blown, Magnetron end of life
Magnetron heater current
Magnetron malfunction,
Transmitter PCB malfunction
Echo
No azimuth signal
Motor fuse blown, Transmitter PCB malfunction
No heading line signal
Motor fuse blown, Transmitter PCB malfunction
No trigger signal
Transmitter PCB malfunction
No video signal
Front-end malfunction,
IF Amp. malfunction
No ARPA signal
Heading
No signal
HDT, HDG, HDM, VTG, RMC, or RMA signal is not
received.
Speed
No signal
VHV, VHW, VBW, VTG, RMC, or RMA signal is not
received.
Panel
Not connected
Operation panel connector is not connected.
Checksum
There is strong noise source near the operation
table.
ATA
Not connected
Integrated ATA PCB is not connected.
AIS
Not connected
Integrated AIS PCB is not connected.
Inter-switch
Not connected
The data cable between two Display units is not
connected.
Preset
No data
No setup value was found in INITIALIZE=> USER
SET LOAD or EXT LOAD.
Memory
Flash memory writing
Setup value could not be saved normally to flash
memory in INITIALIZE=>SETUP SAVE.
Serial port
Download
External load operation failed in Menu INITIALIZE=>
EXT
Upload
External save operation failed in Menu
INITIALIZE=> EXT SAVE.
Checksum
Checksum error occurred in NMEA received data
(displayed in maintenance).