Chapter 5 Detailed setup and additional menu
MDC-2200/2500 Series
5-6
0092625002-06
5.1 Detailed setup items
5.1.1 Marker
5.1.1.1 VRM1 range unit, VRM2 range unit and PI range unit
This function selects a range unit.
You may select desired range unit.
Setting choices : NM, km, sm, RANGE LINK
NM
:
About 1.8 km
sm
:
About 1.6 km
RANGE LINK
: Use the same unit coupled with range.
Refer to “Range unit” (page 5-10) for range unit setting.
5.1.1.2 Stern line
This is used to display the stern line originated from the stern.
This stern line is used to confirm direction and position of the stern.
Setting value: Off, On
5.1.1.3 Cursor shape
This is used to change the shape of the cursor.
You may specify a desired shape from the following list.
Setting value: 21 symbols, cross hair cursor
Symbols
Cross hair cursor consists of “+” shape expanded each lines to the end of the screen.
5.1.1.4 HU cursor and bearing cooperation
This specifies cooperation function of cursor and bearing of own ship in H-Up mode.
A target can be acquired easily by using a rotation function, etc. even when heading of own ship is
changed during acquisition.
Setting value: Off, On