![Koden MDC-1810BB Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/koden/mdc-1810bb/mdc-1810bb_operation-manual_1984715074.webp)
MDC-1840BB/1841BB/1860BB/1810BB/1820BB Series Chapter 5
Operation Manual
Basic Operation
0093142122-10
5-7
HL OFF Key
AUDIO OFF
MENU key
ENT key
5.4 Getting Started
(1) Press the POWER ON/OFF key switch. The red LED lamp lights accordingly and
a 3-minute timer starts to count down. At the same time, the following
information will be shown on the screen.
z
Application software name
z
Range
scale
z
Range ring interval
(2) When the countdown timer finishes, the STANDBY sign will appear on the
screen.
HL OFF
AUDIO
OFF
MENU
ENT
The HL OFF key is used to momentarily remove the Heading Line
from the screen. When the key is pressed and held, the Heading
Line will be removed and, when released it appears again.
The AUDIO OFF key is used to temporarily turn off the audio alarm.
A press of the key will silence the alarm.
The MENU key is used to display the MENU on the screen. Every
press of the key will change the contents of the menu as follows:
First press:
RADAR MENU. This menu contains all the preset
items for radar functions, sensor data display and
EPA/ATA operational settings.
Second press: CAL MENU. This menu contains all technical
settings for the radar operation and Performance
Monitor.
The ENT key is used to activate and fix the selected menu items by
the joystick.