![Koden MDC-1810BB Скачать руководство пользователя страница 133](http://html1.mh-extra.com/html/koden/mdc-1810bb/mdc-1810bb_operation-manual_1984715133.webp)
MDC-1840BB/1841BB/1860BB/1810BB/1820BB Series Chapter 6
Using The Menu
Operation Manual
93142122-07
6-39
6.9.2.4 DUAL
This is the mode that two display units will control one scanner unit.
One of the scanner units and two display will be used on this mode.
Both of the display unit can control the scanner unit such as pulse width, receiver
band width. These control information transferred between two display units each
other. When change the display range on the one display unit such as to 6NM, the
range of the another display unit will be changed to the same range as 6NM
automatically.
You can use radar functions freely on both display units such as EBL, VRM, Gain,
STC control independently.
6.9.3 Operation
1. Press MENU key several times on the standby state. The Interswitch setting screen
shown below will be displayed on the screen. The part indicated as is the item for
setting.
2. Move the part with the joystick to the item for setting, then press ENT key.
The part will blink and shows ready to set.
3. Change the setting with the joystick and press ENT key.
"OTHER" items shows the status of the other radar unit through communication line.
RADAR STATUS SELECT MENU
OWN
OTHER
MODE
INDEPENDENCE
INDEPENDENCE
TYPE
MASTER
MASTER
STATUS
STANDBY
STANDBY
ANTENNA PORT
STBD
6.9.3.1 MODE
Set the radar control mode on this item.
(1) INDEPENDENCE
The display unit controls the scanner unit that is actually connected to the display
unit. No operation effects to the other radar system.
(2) CROSS
The display unit controls the scanner unit that is connected to the other display unit.
No operations effect to the other radar system.