![Koden MDC-1810BB Скачать руководство пользователя страница 112](http://html1.mh-extra.com/html/koden/mdc-1810bb/mdc-1810bb_operation-manual_1984715112.webp)
Chapter 6 MDC-1840BB/1841BB/1860BB/1810BB/1820BB Series
Using The Menu
Operation Manual
6-18
93142122-07
6.4.2 SYSTEM SETUP
This menu is used to select various functional parameters, which are specific to
respective users and their operating conventions.
6.4.2.1
RANGE DISP (Range Scale Display)
This function is used to select the range scale notation system; decimal or fraction.
Example: DECIMAL: 0.125, 0.25...
FRACTION: 1/8, 1/4....
Indication
Meaning
Selection
RANGE DISP
Range Display Mode
DECIMAL, FRACTION
6.4.2.2
BUZZER
This function is used to turn on or off the electronic buzzer.
Indication
Meaning Selection
BUZZER
Alarm Buzzer
OFF, ON
6.4.2.3
LANGUAGE
This function is used to change the Indication Language.
Indication
Meaning
Selection
LANGUAGE
Indication Language
ENG, JPN
6.4.2.4 DELAY (Transmission Timing Adjustment)
This function is used to adjust the transmission delay time in order to coincide the
radar transmission timing with the start of the radar sweep. In practice, the Figure 4.7
in Chapter 4 illustrates the result of the setting, whether it is properly adjusted or not.
To effectively perform this setting, find an appropriate object that is straight across
from your radar.
Indication
Meaning
Selection
DELAY
Radar
Echo
Timing
0 to 99
Carry out the following procedure to set up the proper transmission delay time.
(1) Highlight DELAY and press the ENT key to set up the selection ready status.
(2) Press the Joystick up or the down until a straight picture is shown on the screen.
(3) Press the ENT key to exit.
NOTE:
To momentary silence the audio alarm, press the AUDIO OFF key.
NOTE:
This menu is protected from ordinary operations. To use this function, turn off the
radar se first. Press and hold the MODE key and turn the equipment on. When the standby
condition is established, turn the radar on to enter the following menu functions.