Chapter 4 Setup Procedure
KRD-10
4-12
0093170212-01
4.3.7 Correcting water temperature
The water temperature value input from the water temperature sensor can be corrected and displayed.
(1) Press key until Menu options 1 to 9 appears.
(2) Press
key to select “
4: Compensation
”.
(3) Press
key to select “
6: Water Temperature
”.
(4) Enter a (3-digit) compensation offset by numeric keys.
(5) To correct to (-), move the cursor to the "+/-" place and press the " " key.
(6) Press key.
Initial setup: +00.0
Figure 4.1 Time difference chart
6/E
4/W
MENU
ENT
NOTE:
Press to clear incorrect input. You can
reenter a “+” or “-” sign and numeric
data.