5-8
A-61837 June 2015
Cleaning the imaging
guides — thorough
cleaning
Thorough cleaning of the imaging guides is recommended only as needed.
NOTE: Hold the imaging guides at the green tabs to avoid getting fingerprints
on the imaging guides during the cleaning procedure.
Upper imaging guide
1. Open the scanner cover.
2. Turn the screw to the left on each end of the upper imaging guide and
remove it from its position. Carefully set the imaging guide aside.
3. Carefully vacuum the area between the LEDs.
IMPORTANT: Avoid contact with the LEDs, as contact could cause
damage. Do not insert any objects into the area between the
upper LED strips, as you may damage the reflective mirrors
in the scan module on the illumination system.
4. Clean both the top and bottom of the imaging guide thoroughly with a
Staticide wipe or a “Step 1” Brillianize Detailer wipe.
5. Wipe the imaging guide again with an almost-dry Staticide wipe or a “Step
2” Brillianize Detailer wipe to remove any streaks.
6. Reinstall the upper imaging guide.