A-61997 1 August 2022
31
4 Maintenance
Cleaning the feed rollers
1. Open the scanner cover.
2. Grasp the top edge of the feed roller cover and lift it out of position.
NOTE: Be careful not to damage the paper present sensor when
removing the feed roller cover or cleaning around the feed
roller.
3. Remove the urging roller, then clean it with a roller cleaning pad.
4. Replace the urging roller.
5. Clean the lower feed roller tires without removing them. Rotate the
roller in place with one hand and wipe with the other, using a roller
cleaning pad.
6. Inspect the feed rollers. If the feed roller tires show signs of wear or
damage, replace the feed roller. See “Replacement procedures” on
page 33 for more information.