background image

Wiring Diagram 

Wiring Diagram 

Wiring for single house without lobby phone connection 

Cautions 

1. Pin No.1, 2, 7 & 8 in Main Line Port should be connected between main and sub monitor for internal

call and communication. 

2. For the connection with KIP-603, please refer to the wiring diagram in multi houses (apartment) in next.

3. In extention with KIP-603 (Audio phone), it is not available to make conversation with front door camera.

4. The DIP switch in sub unit should be set as “0”.

Cautions 

- Door lock connection

Only one door lock should be installed and connected to the monitor for front door open. (single house use)
If 2 door locks are installed in parallel connection, these 2 doors will be open at same time.

- Front door camera connection

Be careful in camera connection to the camera ports. As the camera ports have different 2 call sounds,
if camera 1 is connected to the camera port 1 in main monitor and to the camera port 2 in sub monitor, 
main monitor and sub monitor have different 2 call sounds. And camera 1 has 2 different call back tones, too.

- Call sounds : Camera 1 - ‘Ding~Dong~’ 2 times.

Camera 2 - ‘Ddiriri~’ 8 times.

Precautions for Wiring 

As incorrect wiring may cause the device

s non-operation 

or poor communication quality, please carefully 
conduct wiring work. 

When connecting a wiring chord to a terminal, loosen  

screw, insert the end of the chord into the bottom part of 
screw, and tighten the screw. 

When fixing wiring chord, use stapler not to cause damage 

to the chord. 

When using existing wiring, please be cautious not to 

cause disconnection and short-circuit. 

Wiring for multi houses (apartment) using KLP-C100 series Lobby phone.

- Video phone to Video phone wiring in a house.

Cautions 

1. Pin No.6 (data line) in Main Line Port is not connected in sub video phone. 

2. Pin No.1, 2, 3, 4, 5, 7 & 8 in Main Line Port are used in a form of parallel connection between

main monitor and sub monitor.

3. The DIP switch in sub unit should be set as “0”.

Cautions 

- Door lock connection

Only one door lock should be installed and connected to the monitor for front door open. (single house use)
If 2 door locks are installed in parallel connection, these 2 doors will be open at same time.

- Front door camera connection

Be careful in camera connection to the camera ports. As the camera ports have different 2 call sounds,
if camera 1 is connected to the camera port 1 in main monitor and to the camera port 2 in sub monitor, 
main monitor and sub monitor have different 2 call sounds. And camera 1 has 2 different call back tones, too.

- Call sounds : Camera 1 - ‘Ding~Dong~’ 2 times.     Camera 2 - ‘Ddiriri~’ 8 times.

13

14

Содержание KC-C60

Страница 1: ...ality improvement PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control and inspection procedures 2 If this product breaks down during proper use as a result of product defect KOCOM will repair it within one year from date of purchase free of charge 3 The following cases...

Страница 2: ... product in a way of spaying etc Moving equipment be sure that the plug is detached from an outlet For equipment whose cables are connected to terminals please contact your local sales agent or qualified electrician When replacing old fuse with new one do not directly touch it with bare hands Use insulated tools or contact A S center Cautions Warnings for disposal Read this cautions carefully and ...

Страница 3: ...sales agent or A S center Keeping use equipment may cause fire and electric shock Avoid direct exposure to sunlight and store equipment at the place free from dust and high temperature as you can High temperature of equipment may cause fire and electric shock Warnings Warnings Cautions for Use Do not install the product at bathroom or at the place near a washing machine or at other humid places It...

Страница 4: ...s should not contact to the system for multi unit housing In installation be careful that alien substances should not go into the system Before installation be fully aware of wiring specifications of each model In installation be sure that the length and dimension of wiring meet the requirement prescribed in installation manual Excessive strength and external shock may cause mechanical breakdowns ...

Страница 5: ...between indoors and outdoors and also eliminates moisture and condensation on door camera window Stop up P V C pipe using adiabatic substances to prevent air circulation MIC Sending the voice to lobby phone guard phone camera and other equipment connecting to in house line Power LED Communication Button When receiving the call signal from interlocked outside equipment user can communicate with it ...

Страница 6: ...ion Bottom base of One hall Box Surface mount Basic Installation method of Monitor When system is attached to 1 rectangular switch box Standard height monitor Standard height of monitor is ranged 1 450 1 500 from bottom to the center of monitor screen For installation avoid the places where there is any excessive humidity magnetic force dangerous chemicals direct ray of sun and any places near a h...

Страница 7: ...is used 300m Monitor 0 C 50 C Power Source Voltage of Operating Power Lobby Guardroom In house Call Signal Monitoring of Front Door Camera Lobby Phone s Lobby Monitoring Function Call Method Communication Method Image Maintenance Time Number of Wiring Dimensions Communication Distance Guaranteed Operation Temperature KC C60 KC MC35 Front Door Camera KIV 212 Monitor KIV D212 Monitor Component Monit...

Страница 8: ...ration or poor communication quality please carefully conduct wiring work When connecting a wiring chord to a terminal loosen screw insert the end of the chord into the bottom part of screw and tighten the screw When fixing wiring chord use stapler not to cause damage to the chord When using existing wiring please be cautious not to cause disconnection and short circuit Wiring for multi houses apa...

Страница 9: ...oor open button house front door will be opened Monitoring of Front Door Situations 1 Monitoring for Camera 1 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen 2 Monitoring for Camera 2 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen And if pressing the front do...

Страница 10: ...ine button to end communication Users can control chime volume by adjusting 3 level volume switch on videophone In all functions call maintenance time is set for 30 seconds After 30 seconds call signal and images return to stand by mode All communications maintains for 3 minutes After 3 minutes communication automatically returns to stand by mode Instructions for Operation Model KLP 100 KLP P100 K...

Страница 11: ...D MODE It is compatible with the existing units ID is available with 1 63 1000 1963 2000 2963 3000 3963 In this case DIP SWITCH 1 3 4 7 8 12 is put to ON the result is 1 4 8 100 200 2 000 2313 the house No 2313 In this case DIP SWITCH 1 9 11 12 is put to ON the result is 1 400 1000 1401 the house No 1401 In this case DIP SWITCH 1 2 7 is put to ON the result is 1 2 100 103 the house No 103 In this ...

Страница 12: ... DIP SWITCH 2 7 11 12 is put to ON the result is 2 100 1000 2000 3102 the house No 3102 ex8 ex9 ex10 This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certified card The RF card touch area In this ca...

Страница 13: ...is available to set from No 1 1599 1 DIP SW 1 4 it is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 2 DIP SW 5 8 is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 3 DIP SW 9 12 is available by 15 the sum of 1248 100 1 500 10 90 1 9 800 400 200 100 80 40 2...

Страница 14: ... 3 If interphone and video phone are used as Sub phone all of DIP SWITCH should be OFF 4 Don t try to set by force Otherwise errors can occur This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certifi...

Отзывы: