background image

Component

s Name 

BENZENE

THINNER

5 inch LCD 

Identifying visitors  

Precautions for Operation

Keep away from humidifier and
stove.  High  temperature  and
humidity can cause breakdown.

When  cleaning,  never  use  wet
hands,  volatile  benzene  or  paint
thinner.

Keep  picture  clear  by  cleaning
camera  window  frequently  with
soft cloths.

As this device consists of
electronic precision
components, and high voltage
is generated internally, do not
attempt to disassemble. 

Do not drop monitor or door
camera, and avoid strong
impact.

Keep away from devices
generating strong magnetic field
(TV, Speaker, etc.)  (Picture can
be disturbed or blurred and
breakdown can result)

Installation Precautions

Monitor and camera must be installed away from direct 

light and counter light.

Camera must be installed at a place free from rain.

Standard height of monitor must be 1,450mm~1,500mm 

from ground, centered around brawn tube.

Camera should be installed on the wall in which cement 

is completely dry.

If installed during winter season at temperature below

-5

, condensation might be generated inside monitor and 

camera due to temperature difference between indoors 

and outdoors. To prevent breakdown due to such 

condensation, connection should be made in 2 hours or 

more after installation.

Do not install monitor and camera in locations subject to 

direct heating as harmful gases may subsequently be 

emitted in significant amounts. 

Stopping up pipe as above minimizes

temperature  difference  between  indoors  and  outdoors,  and

also  eliminates  moisture  and  condensation  on  door  camera

window.

Stop up P.V.C. pipe using

adiabatic substances, to

prevent air circulation

MIC : Sending the voice to lobby phone,  
guard phone, camera and other equipment 
connecting to in-house line

Power LED

Communication Button

When receiving the call signal from interlocked

outside equipment, user can communicate with

it after pressing this button

Guardroom/Lobby Button 

Speaker 

Door Open Button : Pressing this button 
while communicating, user can 
automatically open the front door and 
common gate

In-house Line Button :
Used in inner line call and communication

Front Door Button :

When receiving the call signal from front door, 
user can communicate with front door after 
pressing this button

Power Switch 

Communication LED

Contrast control switch 

Brightness control switch 

Color tone control switch 

Volume control switch

KC-C60 Camera & KC-MC35 Metal Pinhole Camera

C-Mic

To communicate with Monitor. 

Speaker

When visitor calls, the voice from monitor 
comes out of the speaker. 

Call Button

By pressing the button, the related 
house will be called.

Camera Lens

Clear picture quality realized
by adopting image sensor

Power Lamp

To check power ON/OFF status.  

Option

7

8

Main Line Port from Lobby phone: 
A Port used when multi-home wiring is needed. 
For further information, see the instruction sticker 
or installation specifications

Front Door Opener Port: 
A Port connecting to front door opener

Power Cord: AC 100V - 240V 

Camera 2 Port
A Port connecting to in-house camera

Camera1 Port
A Port connecting to in-house camera

House No. setting switch

Power Cord: DC 17V

±

2V 

DC INPUT(DC 17V

±

2V)

KIV-212

KIV-D212

Содержание KC-C60

Страница 1: ...ality improvement PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control and inspection procedures 2 If this product breaks down during proper use as a result of product defect KOCOM will repair it within one year from date of purchase free of charge 3 The following cases...

Страница 2: ... product in a way of spaying etc Moving equipment be sure that the plug is detached from an outlet For equipment whose cables are connected to terminals please contact your local sales agent or qualified electrician When replacing old fuse with new one do not directly touch it with bare hands Use insulated tools or contact A S center Cautions Warnings for disposal Read this cautions carefully and ...

Страница 3: ...sales agent or A S center Keeping use equipment may cause fire and electric shock Avoid direct exposure to sunlight and store equipment at the place free from dust and high temperature as you can High temperature of equipment may cause fire and electric shock Warnings Warnings Cautions for Use Do not install the product at bathroom or at the place near a washing machine or at other humid places It...

Страница 4: ...s should not contact to the system for multi unit housing In installation be careful that alien substances should not go into the system Before installation be fully aware of wiring specifications of each model In installation be sure that the length and dimension of wiring meet the requirement prescribed in installation manual Excessive strength and external shock may cause mechanical breakdowns ...

Страница 5: ...between indoors and outdoors and also eliminates moisture and condensation on door camera window Stop up P V C pipe using adiabatic substances to prevent air circulation MIC Sending the voice to lobby phone guard phone camera and other equipment connecting to in house line Power LED Communication Button When receiving the call signal from interlocked outside equipment user can communicate with it ...

Страница 6: ...ion Bottom base of One hall Box Surface mount Basic Installation method of Monitor When system is attached to 1 rectangular switch box Standard height monitor Standard height of monitor is ranged 1 450 1 500 from bottom to the center of monitor screen For installation avoid the places where there is any excessive humidity magnetic force dangerous chemicals direct ray of sun and any places near a h...

Страница 7: ...is used 300m Monitor 0 C 50 C Power Source Voltage of Operating Power Lobby Guardroom In house Call Signal Monitoring of Front Door Camera Lobby Phone s Lobby Monitoring Function Call Method Communication Method Image Maintenance Time Number of Wiring Dimensions Communication Distance Guaranteed Operation Temperature KC C60 KC MC35 Front Door Camera KIV 212 Monitor KIV D212 Monitor Component Monit...

Страница 8: ...ration or poor communication quality please carefully conduct wiring work When connecting a wiring chord to a terminal loosen screw insert the end of the chord into the bottom part of screw and tighten the screw When fixing wiring chord use stapler not to cause damage to the chord When using existing wiring please be cautious not to cause disconnection and short circuit Wiring for multi houses apa...

Страница 9: ...oor open button house front door will be opened Monitoring of Front Door Situations 1 Monitoring for Camera 1 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen 2 Monitoring for Camera 2 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen And if pressing the front do...

Страница 10: ...ine button to end communication Users can control chime volume by adjusting 3 level volume switch on videophone In all functions call maintenance time is set for 30 seconds After 30 seconds call signal and images return to stand by mode All communications maintains for 3 minutes After 3 minutes communication automatically returns to stand by mode Instructions for Operation Model KLP 100 KLP P100 K...

Страница 11: ...D MODE It is compatible with the existing units ID is available with 1 63 1000 1963 2000 2963 3000 3963 In this case DIP SWITCH 1 3 4 7 8 12 is put to ON the result is 1 4 8 100 200 2 000 2313 the house No 2313 In this case DIP SWITCH 1 9 11 12 is put to ON the result is 1 400 1000 1401 the house No 1401 In this case DIP SWITCH 1 2 7 is put to ON the result is 1 2 100 103 the house No 103 In this ...

Страница 12: ... DIP SWITCH 2 7 11 12 is put to ON the result is 2 100 1000 2000 3102 the house No 3102 ex8 ex9 ex10 This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certified card The RF card touch area In this ca...

Страница 13: ...is available to set from No 1 1599 1 DIP SW 1 4 it is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 2 DIP SW 5 8 is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 3 DIP SW 9 12 is available by 15 the sum of 1248 100 1 500 10 90 1 9 800 400 200 100 80 40 2...

Страница 14: ... 3 If interphone and video phone are used as Sub phone all of DIP SWITCH should be OFF 4 Don t try to set by force Otherwise errors can occur This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certifi...

Отзывы: