This product is only for home. Do not the product for industrial or military use.

Do not handle the equipment with wet hand, which may cause electric shock. 

Do not place wet or metallic materials on equipment. Water leakage or intrusion of metallic materials may cause fire and 

electric shock. 

Do not block the ventilating opening of equipment or put alien substances into it, which may cause fire and electric shock.

Do not use battery that is not designated or mix new battery with old ones. Insert batteries to fit their polarity. Explosion or 

leakage of battery may cause fire and injury of user.

When visitor's image or voice is not displayed on screen or not sounded from speaker, please check his/her identity before 

opening the door and contact our A/S center.

Do not use equipment when lighting is expected or strokes. It may cause fire and electric shock.

Do not open rear cover, cabinet and cover of equipment. It may cause electric shock.

Do not modify power cable or pull it with excessive strength, which may cause fire and electric shock.

Do not modify equipment. It may cause fire and electric shock.

Call signal may cause damage on user's hearing ability.

Cautions for Abnormality

When power cable is broken (exposure of core or short-circuit), do not fail to replace broken cable with new one. Failure to 

replace broken power cable may cause fire and electric shock.

When detecting any abnormalities in equipment (communication is not available, images do not be displayed on screen, calling

is not available, or abnormal sound is heard), immediately detach plug from an outlet, or turn off circuit breaker or detach 

batteries from equipment (in case that equipment has no plug) before requesting repairs to sales agent or A/S center. Keeping 

connection to power supply may cause fire and electric shock. 

When alien substances go into equipment, immediately detach plug from an outlet, or turn off circuit breaker or detach batteries

from equipment (in case that equipment has no plug) before requesting repair to sales agent or A/S center.

In the case of smoke or smell of unknown origin from equipment, keeping use it may cause fire and electric shock. Detach 

plug from an outlet, or turn off circuit breaker or detach batteries from equipment (in case that equipment has no plug) and be 

sure to check no more smoke or smell from equipment before requesting repair to sales agent or A/S center. Since personal 

repairing work by user may serious accidents. In any case, do not repair equipment with your own hand.  

When dropping equipment or breaking its cabinet, detach plug from an outlet, or turn off circuit breaker or detach batteries 

from equipment (in case that equipment has no plug) before requesting repair to sales agent or A/S center. Keeping use 

equipment may cause fire and electric shock.

Avoid direct exposure to sunlight and store equipment at the place free from dust and high temperature as you can. High 

temperature of equipment may cause fire and electric shock.

Warnings

Warnings

Cautions for Use

Do not install the product at bathroom or at the place near a washing machine, or at other humid places. It may cause fire or 

electric shock.

Do not install the product at the place near a dresser, humidifier or heater. Also avoid the place exposed to spark, heat or 

humidity. All of them may cause fire and electric shock.

Do not install the product at the place exposed to dust, metals and harmful gas such as hydrogen sulfide gas, all of which 

may cause fire and electric shock.

Do not install the product at the place exposed to water and chemicals. This may cause fire and electric shock.

Do not scratch, break or arbitrarily process power cable, which may cause fire and electric shock. Putting a heavy thing on a 

cable, heating it or pulling it may cause impairment on it. 

Do not place power cable at the place near heating equipment. It may cause damage of cable's clothing material, which 

result in fire ad electric shock. When detaching plug from an outlet, do not pull power cable.

Damages on power cable may cause fire and electric shock. When detaching plug from an outlet, please hold the plug 

tightly. 

Do not detach plug from an outlet with wet hand. I may cause electric shock.

When using the existing wiring, be sure of the suitability of it to the product and install the product. Failure to this caution 

may cause fire. 

When moving equipment, be sure that plug is detached from an outlet and communication cable is disconnected. Damage 

on cables may cause fire.  

Voltage other than prescribed rated voltage is not permitted, which cause fire and electric shock. 

Do not use power terminal of product's main body in other equipment than prescribed ones. It may cause fire and short-

circuit.

In wiring work, use the designated wiring materials. 

Wiring work using other materials than designated ones may cause fire.

The equipment without waterproof marking shall not be installed at the place water leaks. It may cause electric shock and 

short circuit.

When working, be sure that power is disconnected. Failure to disconnect power may cause electric shock.

Be sure that the power cable is connected and earths according to designated method. Failure to connection and earth may 

cause fire.

Do not connect power to other terminals than designated ones.

It may cause fire and electric shock.

When building a system with the product, do not connect the product other equipment than designated one. It may cause 

fire.

When installing A/C switch, do work after removing the substance that may cause short circuit or electric shock.

Before installing or providing A/S service, be sure that the power is disconnected.

Cautions for Use

3

4

Содержание KC-C60

Страница 1: ...ality improvement PRODUCT MODEL DATE PURCHASED WARRANTY PERIOD AGENCY ADDRESS KOCOM Warranties the original purchaser of this product as follows 1 This product is produced under strict quality control and inspection procedures 2 If this product breaks down during proper use as a result of product defect KOCOM will repair it within one year from date of purchase free of charge 3 The following cases...

Страница 2: ... product in a way of spaying etc Moving equipment be sure that the plug is detached from an outlet For equipment whose cables are connected to terminals please contact your local sales agent or qualified electrician When replacing old fuse with new one do not directly touch it with bare hands Use insulated tools or contact A S center Cautions Warnings for disposal Read this cautions carefully and ...

Страница 3: ...sales agent or A S center Keeping use equipment may cause fire and electric shock Avoid direct exposure to sunlight and store equipment at the place free from dust and high temperature as you can High temperature of equipment may cause fire and electric shock Warnings Warnings Cautions for Use Do not install the product at bathroom or at the place near a washing machine or at other humid places It...

Страница 4: ...s should not contact to the system for multi unit housing In installation be careful that alien substances should not go into the system Before installation be fully aware of wiring specifications of each model In installation be sure that the length and dimension of wiring meet the requirement prescribed in installation manual Excessive strength and external shock may cause mechanical breakdowns ...

Страница 5: ...between indoors and outdoors and also eliminates moisture and condensation on door camera window Stop up P V C pipe using adiabatic substances to prevent air circulation MIC Sending the voice to lobby phone guard phone camera and other equipment connecting to in house line Power LED Communication Button When receiving the call signal from interlocked outside equipment user can communicate with it ...

Страница 6: ...ion Bottom base of One hall Box Surface mount Basic Installation method of Monitor When system is attached to 1 rectangular switch box Standard height monitor Standard height of monitor is ranged 1 450 1 500 from bottom to the center of monitor screen For installation avoid the places where there is any excessive humidity magnetic force dangerous chemicals direct ray of sun and any places near a h...

Страница 7: ...is used 300m Monitor 0 C 50 C Power Source Voltage of Operating Power Lobby Guardroom In house Call Signal Monitoring of Front Door Camera Lobby Phone s Lobby Monitoring Function Call Method Communication Method Image Maintenance Time Number of Wiring Dimensions Communication Distance Guaranteed Operation Temperature KC C60 KC MC35 Front Door Camera KIV 212 Monitor KIV D212 Monitor Component Monit...

Страница 8: ...ration or poor communication quality please carefully conduct wiring work When connecting a wiring chord to a terminal loosen screw insert the end of the chord into the bottom part of screw and tighten the screw When fixing wiring chord use stapler not to cause damage to the chord When using existing wiring please be cautious not to cause disconnection and short circuit Wiring for multi houses apa...

Страница 9: ...oor open button house front door will be opened Monitoring of Front Door Situations 1 Monitoring for Camera 1 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen 2 Monitoring for Camera 2 If pressing the front door button once on the monitor the image from camera 1 port is displayed on the monitor screen And if pressing the front do...

Страница 10: ...ine button to end communication Users can control chime volume by adjusting 3 level volume switch on videophone In all functions call maintenance time is set for 30 seconds After 30 seconds call signal and images return to stand by mode All communications maintains for 3 minutes After 3 minutes communication automatically returns to stand by mode Instructions for Operation Model KLP 100 KLP P100 K...

Страница 11: ...D MODE It is compatible with the existing units ID is available with 1 63 1000 1963 2000 2963 3000 3963 In this case DIP SWITCH 1 3 4 7 8 12 is put to ON the result is 1 4 8 100 200 2 000 2313 the house No 2313 In this case DIP SWITCH 1 9 11 12 is put to ON the result is 1 400 1000 1401 the house No 1401 In this case DIP SWITCH 1 2 7 is put to ON the result is 1 2 100 103 the house No 103 In this ...

Страница 12: ... DIP SWITCH 2 7 11 12 is put to ON the result is 2 100 1000 2000 3102 the house No 3102 ex8 ex9 ex10 This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certified card The RF card touch area In this ca...

Страница 13: ...is available to set from No 1 1599 1 DIP SW 1 4 it is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 2 DIP SW 5 8 is available by 15 the sum of 1248 In case of 2 digits from 9 are available by No 9 And 10 15 A F HEX code s setting is 9 3 DIP SW 9 12 is available by 15 the sum of 1248 100 1 500 10 90 1 9 800 400 200 100 80 40 2...

Страница 14: ... 3 If interphone and video phone are used as Sub phone all of DIP SWITCH should be OFF 4 Don t try to set by force Otherwise errors can occur This is for the RF module lobby phone 1 The common gate can be opened by touching the registered RF card onto the lobby phone Option 2 Register RF card in the guard room 3 Don t make the card curved or shocked Otherwise error can occur 4 Use only the certifi...