Installation & Operation Manual
85
X1-7
ON/OFF
SWITCH
1 2 3 4 5
G
R
R W
R
T
W
BK
Y/BK
BL
BLOWER
-T
HIGH LIMIT SENSOR S1b
OPERATING SENSOR S1a
INLET SENSOR S2
FLUE SENSOR S3a
FLUE SENSOR S3b
INTEGRATED
CONTROL
BK
Y
GAS VALVE
@24VAC
SPARK
ROD
TRANSFORMER
TR2
G
HIGH VOLTAGE SPARK LEAD
CAUTION
FLAME SENSOR
ALARM
CONTACTS
RUN-TIME
CONTACTS
24 VAC LOUVER
RELAY COIL
LOUVER
PROVING SWITCH
GAS PRESSURE
SWITCH
FLOW
SWITCH
TANK
THERMOSTAT
9
10
7
8
5
6
3
4
1
2
SYSTEM
SENSOR
OUTDOOR
SENSOR
TANK
SENSOR
CASCADE
A
B
SHIELD
SHIELD
0-10V
+
-
BMS
IN
0-10V
+
-
SYS PUMP
IN
0-10V
+
-
BLR PUMP
OUT
0-10V
+
-
RATE
OUT
MODBUS
OPTION
A
B
SHIELD
SHIELD
P/BK
Y
W/R
23
24
26
27
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
CN5-15
CN5-1
CN5-9
CN5-2
CN5-10
CN5-3
CN5-11
CN5-12
CN5-4
CN5-5
CN5-15
CN5-13
CN5-6
CN5-14
CN5-7
X5-7
X5-16
X5-8
X5-15
X5-9
X5-1
X5-2
X5-10
X5-11
X5-4
X5-12
X5-6
X5-5
X5-13
X5-14
X2-2
X2-1
BK
Notes:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105°C. Exceptions: Replacement high vo ltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead
or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using
diagrams to troubleshoot unit.
WIRING DIAGRAM
100209663 REV B
BOX DEPICTS
OPTIONAL ITEMS
X4-16
X4-7
X4-14
X4-6
X4-13
X4-5
X4-12
X4-11
X4-4
X4-3
X4-8
X4-10
X4-2
X4-9
X4-1
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
CONNECTION
BOARD
CN6
X6
HIGH VOLTAGE
LOW VOLTAGE
120 VAC
X-7
BOX DEPICTS
DUAL SENSOR
SINGLE HOUSING
MODBUS BOARD
MTR-01
CN
8-1
CN
8-2
CN
8-3
X6
-3
X6
-2
X6
-1
X6
-4
X9-1
X9-2
X9-3
X9-4
X4-1
X4-2
X4-3
X4-4
X5-1
X5-2
X1-1
X1-2
X1-3
BK
W
G
R BLG
-T
-T
-T
-T
SHIELD
GROUNDING
JUMPER
O
GY
G
R/BK
W/BK
GY
PR
1 2
G
3
BELL J
U
MPER
ALAR
M BE
LL
SILENCI
N
G SWITCH
JUNCTION
BOX
DHW
PUMP
BOILER
PUMP
SYSTEM
PUMP
BOX DEPICTS
OPTIONAL
ITEMS
G
G
G
L
GND
N
120V
SUPPLY
X1-3
X1-4
X1-2
X1-5
X1-6
X1-8
X1-1
BK
OR
W
W
W
BR
PR
W
L
N
L
N
L
N
L
N
O
AIR PRESSURE SWITCH
O/BK
HEAT/LOOP
DEMAND
3
HEAT/LOOP
DEMAND
2
HEAT/LOOP
DEMAND
1
P
24 VAC DHW RECIRC
PUMP RELAY COIL
17
18
21
22
19
20
15
16
13
14
11
LOW
WATER
CUT-OFF
24 VAC
COM
CN7-1
CN7-2
CN7-3
CN7-4
BK
DHW
RECIRC
SENSOR
30
29
12
CN9
BL
Y
Figure 13-2 Wiring Diagram
13
Diagrams
(continued)