Zero Point:
Use DIP4, DIP5, and DIP6 to set the number to the left of the decimal
point for the zero point. Use the “Zero” rotary switches (Z) to set the
numbers to the right of the decimal point (x.00 ... x.99).
Note
Cover the switches with the included self-adhesive polyimide tape
after completion of confi guration.
Adjustment Ranges
[mV/V]
0
0.99
1.99
2.99
3.99
-0.99
-1.99
-2.99
-3.99
Range
DIP S1
4 5 6
–(3+Z/100)
–(2+Z/100)
x
–(1+Z/100)
x
–(0+Z/100)
x x
0+Z/100
x
1+Z/100
x
x
2+Z/100
x x
3+Z/100
x x x
Output Signals:
Adjust the output signal using the switches DIP7, DIP8.
Within these ranges the exact value is specified by
the rotary switches (“Z”).