2 Installation
The installation, start-up, operation, and maintenance of the SL-IV+ waterjet
pump requires complete reading and study of this manual to understand the
system in detail.
2.1 Installation
Overview
Read the manual and become familiar with the operation of each component
and its nomenclature.
Understand the complete system and its function before operating it.
Safety procedures and safe practices must be followed during installation,
operation, and maintenance of the SL-IV+ waterjet pump.
2.1.1 Buyer Obligations
Equipment installation requires cooperation between the user and Ingersoll-
Rand Waterjet. If on-site support is requested, the KMT Waterjet Systems
Service Department will require the following tasks be accomplished before
arrival at the customer site:
•
The waterjet cutting equipment should be uncrated, positioned and leveled,
with electrical and fluid services brought to the unit.
•
Provide and install power drops with fused disconnects sized to the
equipment power requirements.
•
Provide and install pneumatic drops with manual shutoff valves.
•
Provide all mounting and support brackets and hardware for high pressure
tubing runs.
•
Provide and install water conditioning equipment necessary to meet water
purity requirements. Provide and install manual shutoff valves.
•
Provide and install necessary cooling water inlet/outlet, and drain water
connections to the intensifier pump, and/or cutting equipment and manual
shut-off valves.
•
Provide suitably located and sized drains and proper disposal of waste
water.
•
Provide, install and connect wiring between the intensifier pump(s), and the
cutting station control system.
•
KMT Waterjet supplies a pre-filled hydraulic system. If fluid is low or empty
due to leakage during transit, the system must be filled per specifications.
2.1.2 Seller Obligations
If KMT Waterjet Service is requested, the following tasks will be the
responsibility of the KMT Waterjet technician at installation.
•
Insure site preparation is satisfactory.
•
Remove internal strapping and blocking material.
Содержание STREAMLINE SL-IV PLUS
Страница 44: ...SECTION 6 LOW PRESSURE WATER May 2003 6 4 05148390 Figure 6 2 LP Cutting Water Supply Circuit ...
Страница 78: ...SECTION 7 HIGH PRESSURE WATER May 2003 p 7 30 49831951 ...
Страница 82: ...SECTION 8 ELECTRICAL SYSTEM Aug 2002 p 8 4 49836323 ...
Страница 111: ...SECTION 12 PARTS LISTS July 2003 page 12 5 49836349 ...
Страница 113: ...SECTION 12 PARTS LISTS July 2003 page 12 7 49836349 ...
Страница 115: ...SECTION 12 PARTS LISTS July 2003 page 12 9 49836349 ...
Страница 117: ...SECTION 12 PARTS LISTS July 2003 page 12 11 49836349 ...
Страница 119: ...SECTION 12 PARTS LISTS July 2003 page 12 13 49836349 ...
Страница 121: ...SECTION 12 PARTS LISTS July 2003 page 12 15 49836349 ...
Страница 123: ...SECTION 12 PARTS LISTS July 2003 page 12 17 49836349 ...
Страница 125: ...SECTION 12 PARTS LISTS July 2003 page 12 19 49836349 ...
Страница 127: ...SECTION 12 PARTS LISTS July 2003 page 12 21 49836349 ...
Страница 129: ...SECTION 12 PARTS LISTS July 2003 page 12 23 49836349 ...
Страница 131: ...SECTION 12 PARTS LISTS July 2003 page 12 25 49836349 ...
Страница 133: ...SECTION 12 PARTS LISTS July 2003 page 12 27 49836349 ...
Страница 135: ...SECTION 12 PARTS LISTS July 2003 page 12 29 49836349 ...
Страница 137: ...SECTION 12 PARTS LISTS July 2003 page 12 31 49836349 ...
Страница 139: ...SECTION 12 PARTS LISTS July 2003 page 12 33 49836349 ...
Страница 141: ...SECTION 12 PARTS LISTS July 2003 page 12 35 49836349 ...
Страница 143: ...SECTION 12 PARTS LISTS July 2003 page 12 37 49836349 ...
Страница 145: ...SECTION 12 PARTS LISTS July 2003 page 12 39 49836349 ...
Страница 146: ......
Страница 147: ......