![KME DAP 26 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/kme/dap-26/dap-26_user-manual_1979576020.webp)
All-pass filters do not change the frequency response of an acoustoelectric system at
all but the phase response. They can be used to influence the phase response. This
is a complex field in filter theory and so all-pass filters should only be used by
engineers who have ‘enough’ theoretical background. Incorrect all-pass filtering may
not damage the sound system but affect the sound in a negative way.
The mode of action is presented here:
AP I
All-pass filter Type I
This filter creates a quite flat, smooth phase shift over the whole frequency range with
a characteristic 90° pole at the centre frequency.
mid frequency
20
Hz -
44 kHz
AP II
All-pass filter Type II
This filter creates a steep phase shift at the centre frequency. The course of the
phase curve may be affected by the
„Q“
factor.
mid frequency
20
Hz -
44 kHz
bandwidth „Q“
0,1
-
20