26
EN
G
L
ISH
INITIAL START-UP
Pellet loading and connection to the electricity network
Perform the following operations:
−
Connect the stove to the electrical system using the cable supplied;
−
Position the switch on the rear side of the stove on “
׀
” (on);
−
Fill the pellet tank; for the initial start-up use that specified in “
MENU 06
– FIRST LOADING”
in order
save the time required for filling up the screw feed channel completely (this operation must be
performed every time the stove is without pellets);
−
Switch the stove on using the relevant ignition button on the Control Panel. See the instructions below.
We recommend using high-quality pellets so as avoid jeopardising the stove's functionality. Damages
caused by poor-quality pellets shall not be covered by the warranty.
Ignition cycle
Pressing button 4 (ON/OFF) for a few seconds, the ignition cycle of the appliance starts
.
After a while, the
display shows
“START”,
and the flue gas intake device and the ignition resistance switch on. After a few
seconds, the appliance enters a preheating phase (
“PREHEATING”)
which allows the ignition resistance to
get hot enough before the loading of the pellet onto the crucible.
The appliance goes into
“FLAME STAND-
BY”
after the pre-load phase, starting to load the pellet onto the crucible at regular intervals of time.
Once the
flame has been lit, the message
“FIRE”
is displayed on the
screen. This step ensures that the fire is spread
evenly across the crucible, and consequently burning all the fuel that stayed unburnt at previous stages. After
such phases, the appliance enters the work mode at the pre-set power value.
In case of ignition failure, the alert message
“NO IGNITION”
is displayed.
The alarm may also occur if the crucible is dirty; in this case, clean the crucible and re-start.
Summary:
The ignition cycle lasts 25 minutes max. and is divided into four steps:
1 - START
:
Flue-gas exhauster switching on
2 - PREHEATING
:
Waiting the ignition resistance to get hot.
3 - PELLET P-LOAD
:
Pellet pre-load (initial continuous load)
and ignition resistance powered on.
(Not preset at the factory)
4 - FLAME STAND-BY
:
pellet load (intermittent load) and ignition
resistanceworking.
5 - FIRE PRESENT
:
Ignition resistance powered off and flame
stabilization
After the ignition cycle the appliance switches into working mode at the power output which was set during
ignition via buttons 1 and 2.