31
EN
G
L
ISH
“Various calibrations” (Menu M8 – 2) (Firmware H02_250117)
Parameter
Description
Display writing
Measurement
Value field
Database o0
Pr38
Re-ignition block
RE-IGNITION BLOCK
Minutes
0 – 10
5
Pr39
Flue gas extractor switch-off time
EXTRACTOR OFF
MINUTES
Minutes
0 – 20
10
Pr40
Pre-loading time in ignition
IGNITION PRE-LOADING
Seconds
0 – 255
0
Pr41
Stand-by time after pre-loading
STAND-BY AFTER PRE-
LOADING
Seconds
0 – 255
0
Pr42
Extractor speed in pre-loading phase
EXTRACTOR PRE-
LOADING
RPM
600 – 2800
2800
Pr43
“SET AMBIENT”
ON temperature
hysteresis
DELTA AUTO
°C
0.0 – 15.0
2.0
Pr44
Economy switch-off delay (timer after
reaching
“SET AMBIENT”
)
DELAY AUTO
Minutes
2 – 120
2
Pr45
Power change delay
POWER CHANGE
Seconds
0 – 60
30
Pr46
Enabling of remote control
ENABLE REMOTE
On – off
On – off
OFF
Pr47
Keypad block enabling
KEYS BLOCK-EN
On – off
On – off
OFF
Pr48
Automatic re-ignition after blackout
BLACKOUT
Seconds
0 – 60
30
Pr49
Room sensor calibration
SENSOR OFF-SET
°C
- 9 – 9
0
Pr50
Preheating time
PRE-HEAT TIME
Seconds
0 – 360
300
Pr51
Extractor speed in preheating time
PRE-HEAT GASSPEED
RPM
500 – 2800
2800
“Pellet type” (Menu M8 – 3) (Firmware H02_250117)
Parameter
Description
Display writing
Measurement
Value field
Database o0
Pr54
Pellet loading percentage at the various
working powers
PELLET LOADING
-
- 9 – 9
0
“Chimney type” (Menu M8 – 4) (Firmware H02_250117)
Parameter
Description
Display writing
Measurement
Value field
Database o0
Pr55
Flue gas extraction speed percentage
at the various working powers
EXTRACTOR CHIMNEY
-
- 9 – 9
0
Содержание DEA ECO 8
Страница 2: ...1...
Страница 37: ......
Страница 71: ......
Страница 105: ......
Страница 139: ...34 ESPA OL...
Страница 142: ......
Страница 143: ...WWWWWWWWW KLOVER SRL Via A Volta 8 37047 San Bonifacio VR internet www klover it e mail klover klover it...