![Kiturami KRP-20PA Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/kiturami/krp-20pa/krp-20pa_installation-and-operation-manual_1974120026.webp)
www.kiturami.co.kr
Main Controller(NPB-150) – Description
kituami
Page 25
○ Functional Description (During initial power-up - Stop the ignition for about
12 seconds, including the initial flame section)
1. Secondary controller (HOT-4000P) power OFF
Function
Detecting method
Display
Contents
Releasing method
freeze
and burst
Detect water temperature
sensor(10℃)
x
Circulation
pump
ON
Over 12℃ Auto reset
Over
heating
warning
Detect water temperature
sensor(83℃)
x
Circulation
pump
ON
Lower than 81℃ Auto reset
Detect overheat sensor(83℃)
Lower than 81℃ Auto reset
Over
heating
error
Detect water temperature
sensor(96℃)
x
Circulation
pump
ON
Lower than 81℃ Auto reset
Detect overheat sensor(96℃)
Lower than 81℃ Auto reset
2. automatic room thermostat (CTR-5700PLUS) powers OFF
Function
Detecting method
Display
Contents
Releasing method
freeze
protection
system
Detect water temperature
sensor(10℃)
x
Circulation
pump
ON
Over 12℃ Auto reset
Detect water temperature
sensor(7℃)
Burner ON
Circulation
pump
ON
Over 25℃ Auto reset
Over
heating
warning
Detect water temperature
sensor(83℃)
x
Circulation
pump
ON
Lower than 81℃ Auto reset
Detect overheat sensor(83℃)
Circulation
pump
ON
Lower than 81℃ Auto reset
Over
heating
error
Detect water temperature
sensor(96℃)
“96”
Circulation
pump
ON
Manual reset
Detect overheat sensor(96℃)
Circulation
pump
ON