- 10 -
Fix the bearing cartridge DE (241). The outer face of the bearing
should touch the shoulder provided in the cartridge.
Fix the bearing cover DE to the cartridge by tightening the bolts (631).
Insert coupling spacer in case of DSM-3, DSM-1E, 2E, 3ME, 65 DSM-
315-M, DSM-5B and DSM-6.
Fit coupling key (321) on the shaft.
Fix pump coupling half (390) on the shaft and tighten the same by
coupling nut (332) in case of DSM-3, DSM-1E, 2E, 3ME, 65 DSM-
315-M, DSM-5 and DSM-6 pumps.
In case of DSM 150-45 pump, bearing cartridges are put on the shaft prior
to mounting of bearings.
This completes the assembly of rotating unit.
6.4.5
Now lift the above rotating unit and fit it properly in the lower half casing
so that pins (611, 610.1) take their proper seating.
6.4.6
Fit the two bearing caps by means of bolts. Rotate the whole unit and see
that there is no friction between rotating and stationery parts.
6.4.7
Cut the paper packing to match the profile at the upper and lower half
casing. Put the paper packing (dipped in linseed oil) on the lower half
casing. Keep the upper half casing gently and neatly without disturbing
the impellers or packing etc. Insert the taper pins so that the two halves
of the casings will take their proper seat.
6.4.8
Now insert the bolts and nuts for upper half and lower half casing and
tighten them. While tightening the nuts, take care to tighten the diagonally
opposite bolts. Rotate the impeller by rotating coupling and see that there
is no friction between the rotating unit and stationery parts.
6.4.9
Insert the eye bolts in their positions and fix them by tightening the bolts
(593, 581). Insert the stuffing box packing staggering the joints in 180
and push each ring inside as far as possible.
6.4.10
Insert the lantern ring at non-driving end side at a position indictaed in
technical data (e.g. 2+L+3).
6.4.11
Fix gland (split type) (223) on the shaft. Tighten the stuffing box packing
by tightening the gland nuts (300).
While tightening the glands, please see that the unit can be rotated by
hand.
6.4.12
Connect the copper pipes for sealing connection (562). Fix air vents,
priming funnel and grease cups. Fix the nameplate (670) on NDE cartridge.
This completes the re-assembly.
While ordering spares, specify nameplate details, particularly machine numbers given
in enclosed spare parts list. Also specify quantity required.
Содержание 65-DSM 315M
Страница 15: ...14 CROSS SECTION ASSEMBLY OF DSM 1E CCW CROSS SECTION ASSEMBLY OF DSM 2E CCW...
Страница 17: ...16...
Страница 18: ...17 CROSS SECTIONAL ASSEMBLY OF DSM 3ME CCW NOTE ALSO FOR DSM 3 3 ME...
Страница 29: ...1...
Страница 30: ...2...
Страница 35: ...7 4 5 7 Technical data chart Position of lantern ring from Impeller side NDE side 2 L 3 for gland packing pumps...
Страница 43: ...15 7 1 2 NON THRU BORE TYPE PUMP Mechanical seal type...
Страница 46: ...18...
Страница 47: ...19...
Страница 48: ...20...
Страница 49: ...21...
Страница 50: ...22...
Страница 51: ...23...
Страница 52: ...24...
Страница 53: ...25...
Страница 54: ...26...