Scrambler Function
Built in voice security system to avoid being wiretapped.
Press [F],[3] and rotate the Channel Selector to select the
scrambler function ON or OFF, then press [OK] or [PTT] to keep the
setting. If select ON, LCD display
VOX Function
In the stand-by state, if the VOX function is activated, LCD display
VOX
. If the voice higher than the default, the transceiver auto
switch to the transmitting state; if lower than the default, the
transceiver returns to the receiving mode within 2 seconds. In the
strong noise surroundings, It may result in mis-transmission, so please
set the VOX sensitivity in a suitable level.
Adjust VOX Sensitivity:
Press [F], [6], LCD display
VOX
and the current VOX sensitivity
level, rotate the Channel Selector to select the VOX sensitivity level
(0
9 or OFF), then press [OK] or [PTT] to keep the setting.
Note: This function will be more perfect with an earphone.
Step Size
In the full-frequency display mode, rotate the Channel Selector to
select the desired frequency, while scanning, the frequency will
steadily increase or decrease according to the
step size
you have
set.
Step Size Setting:
Press [F], [9] to enter the
step size
setting, rotate the Channel
Selector to select a step size (5, 6.25, 10, 12.5, 25, unit: KHz), then
press [OK] or [PTT] to keep the setting.
Reverse Frequency Function
While the Reverse Frequency is activated, the transmitting frequency
and receiving frequency are interchangeable, that's convenient for
you to manually check the signal strength from the station which
connects with the repeater.
Switch the Reverse Frequency Function:
Press [F], [0], LCD display
R
, the Reverse Frequency function is
ON; press [F], [0] again,
R
disappears, the function is OFF.
Note: while changing the channel or setting the Scan function on, the
Reverse Frequency function will be OFF automatically.
Lamp Function
You can set lamp function AUTO, ON or OFF.
AUTO: To light the screen, press [lamp] , this moment, press any key
other than [PTT] and [MONI], the light will be ON for about 5 seconds;
press [lamp] again to turn off the light immediately.
ON: press [F], [lamp], the light will remain ON until you press [F],
[lamp] again.
Alarm Function
Under the stand-by status, the transceiver will emit alert with high
decibel, and meanwhile emit alert to other transceivers with the same
frequency in the group and display its ANI code on them. Press [SCN]
again to stop it.
Wired Clone Function
This function is useful to clone data between transceivers.
1)Connect two transceivers by a data wire.
2)Turn on the sub-transceiver which will receive data and enter the
user mode.
20
19