1. SAFETY INSTRUCTIONS
The muffler becomes very hot during operation and
remains hot for a while after stopping the engine. Be
careful not to touch the muffler while it is hot.Let the
engine cool before storing the generator indoors.
The engine exhaust system will be heated during
operation and remain hot immediately after stopping the
engine.To prevent scalding, pay attention to the warning
marks attached to the generator.
Our generators are designed to give safe anddependable
service if operated according to instructions.
Read and understand the Owner's Manual before
operating the generator. Failure to do so could result in
personal injury or equipment damage.
Exhaust gas contains poisonous carbon monoxide.
Never run the generator in an enclosed area.
Be sure to
provide adequate ventilation.When installed in ventilated
protection are to be observed.
W A R N I N G
WARNING
W A R N I N G
W A R N I N G
The conditions of generator rated output:
Altitude: 0 m Ambient temperature: 25
Relative humidity: 30%
Ambient modified coefficient: C (Relative humidity 30%)
Note: When the relative humidity is 60%, the modified coefficient is C-0.01
When the relative humidity is 80%, the modified coefficient is C-0.02
When the relative humidity is 90%, the modified coefficient is C-0.03
When the relative humidity is 100%, the modified coefficient is C-0.04
Counting example:
When the rated power of generator is P =5KW, altitude is 1000m, ambient
N
temperature is 35
, relative humidity is 80%, the rated power of generator is:
P=P
(C-0.02) = 5
(0.82-0.02) = 4KW
N
Modified coefficient table
of ambient condition power
Ambient temperature (
)
Altitude
(m)
0
500
1000
2000
3000
4000
25
1
0.93
0.87
0.75
0.64
0.54
30
0.98
0.91
0.85
0.73
0.62
0.52
35
0.96
0.89
0.82
0.71
0.6
0.5
40
0.93
0.87
0.80
0.69
0.58
0.48
45
0.90
0.84
0.78
0.66
0.56
0.46
14. APPENDIX
Operate carefully and make sure users and others safety.