Oil rule

Upper Lever

Oil Filler Hole

2.Check the fuel level 

WARNING

Gasoline is extremely flammable and is explosive under certain conditions.
Refuel in a well-ventilated area with the engine stopped. Do not smoke or 
allow flames or sparks in the area where the engine is refueled or where 
gasoline is stored.
Do not overfill the fuel tank (there should be no fuel above the upper limit 
mark). After refueling, make sure the tank cap is closed properly and 
securely.
Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may ignite, 
If any fuel is spilled, make sure the area is dry before starting the engine.
Avoid repeated or prolonged contact with skin or breathing of vapor. KEEP 
OUT OF REACH OF CHILDREN.

Upper Limit

Lower Limit

Use automotive gasoline (Unleaded or lowleaded is preferred to minimize combus 

tion chamber deposits).

If the fuel level is low, refuel the fuel tank until the level as specified.

Never use an oil/gasoline mixture or dirty gasoline. Avoid getting dirt, dust or water 

in the fuel tank. After refueling, tighten the fuel filler cap securely.

9.TRANSPORTING/STORAGE 

To prevent fuel spillage when transporting  or during temporary storage, the generator 

should be secured upright in its normal operating position, with the engine swith OFF. Turn 

the cap lever fully counterclockwise to the "OFF" position.

Gasoline is extremely flammable and explosive undercertain conditions.

Do not smoke or allow flames or sparks in the area.

When transporting the generator:

Do not overfill the tank (there should be no  fuel in the filler neck).

Do not operate the generator while it is on  a vehicle. Take the generator off the 

vehicle and use it in a well ventilated place.

Avoid a place exposed to direct sunlight when putting the   generator on a 

vehicle. if the generator is left in an enclosed  vehicle for many hours, high 

temperature in-side the vehicle could cause fuel to vaporize  resulting in a 

possible explosion. Do not drive on a rough  road for an extended period with 

the generator on board, if you must transport the  generator on a rough road, 

drain the fuel from the generator beforehand.

Before storing the unit for an extended period:

1. Be sure the storage area is free of excessive humidity and dust.

2.Drain out the fuel completely. 

WARNING

WARNING

Drain Screw

WARNING

 Running the engine with insufficient oil can cause serious engine damage.

 

The Low Oil Alarm System will automatically stop the engine before the oil 

level falls below the safe limit. However, to avoid the inconvenience of an 
unexpected shutdown, it is still advisable to visually inspect the oil level 
regularly.

Содержание Sinamaster I G2600

Страница 1: ...S I N E M A S T E R DIGITAL INVERTER GENERATOR IG2600 IG2600h WUXI KIPOR POWER CO LTD R R...

Страница 2: ......

Страница 3: ...e operating this generator Operate only in well ventilated areas Exhaust gas contains poisonous carbon monoxide and can be deadly Always stop engine before refueling Wait 5 minutes before restarting C...

Страница 4: ...icaction 4 Pre operation Check 5 Starting the Engine High altitude operation 6 Generator Use 7 Stopping the Engine 8 Maintenance 9 Transporting Storage 10 Troubleshooting 11 Specifications 12 Electric...

Страница 5: ...d protection are to be observed WARNING WARNING WARNING WARNING The conditions of generator rated output Altitude 0 m Ambient temperature 25 Relative humidity 30 Ambient modified coefficient C Relativ...

Страница 6: ...when utility power is restored the generator may explode burn or cause fires in the building s electrical system WARNING Always make a pre operation inspection before you start the engine You may prev...

Страница 7: ...carefully If a label comes off or becomes hard to read contact you dealer for a replacement Safety caution 12 ELECTRIC DIAGRAM Sub winding Main winding Stepping motor Charging widning DC Receptacle En...

Страница 8: ...0 2 3 2 6 Single phase 60 240 9 6 Engine Model Type KG166 Type Displacement BorexStroke Compression ratio Rated power kW r min Ignition system Spark plug Starting system Fuel type Fuel consumption g k...

Страница 9: ...light ON NO NO YES YES YES NO Take the generator to an authorized dealer Take the generator to an authorized dealer Check the electrical appliance or equipment for any defects Replace the electrical...

Страница 10: ...ottle switch to the OFF position to reduce voltage vibration In DC operation turn the Smart throttle switch to the OFF position 10 TROUBLESHOOTING When the engine will not start Is there fuel in the t...

Страница 11: ...Grip a Drain all gasoline from the fuel tank into an approved gasoline container b Turn the engine switch ON and loosen the carburetor drain screw and drain the gasoline from the carburetor into a su...

Страница 12: ...red upright in its normal operating position with the engine swith OFF Turn the cap lever fully counterclockwise to the OFF position Gasoline is extremely flammable and explosive undercertain conditio...

Страница 13: ...ts and corrosion inhibitors NOTE nFuel system damage or engine performance problems resulting from the use of fuel that contain alcohol is not covered under the warranty We cannot endorse the use of f...

Страница 14: ...card it if the insulator is cracked or chipped Clean the spark plug with a wire brush if it is to be reused 6 Measure the plug gap with a feeler gauge The gap should be 0 6 0 7 mm 0 024 0 028in Correc...

Страница 15: ...he engine Before starting the engine disconnect the load from the DC terminals NOTE 1 Turn the fuel cap lever fully clockwise to the ON position 2 Turn the engine switch to the ON position Spark Plug...

Страница 16: ...under certain conditions A dirty air cleaner will restrict air flow to the carburetor T o prevent carburetor malfunction service the air cleaner regularly Service more frequently when operating the ge...

Страница 17: ...ir fuel mixture 5 Move the choke lever to the RUN position after the engine warms up If the engine stops and will not restart check the engine oil level before troubleshooting in other areas CAUTION C...

Страница 18: ...ble laws and electrical codes improper connections can allow electrical current from the generator to backfeed into the utility lines Such backfeed may electrocute utility company workers or others wh...

Страница 19: ...e that all appliances are in good working order before connecting them to the generator If an appliance begins to operate abnormally becomes sluggish or stops suddenly turn off the generator engine sw...

Страница 20: ...Before connecting an appliance to the generator check that it is in good order and that its electrical rating doe not exceed that of the generator Then connect the power cord of the appliance and sta...

Страница 21: ...en the equipment to be used isswitched on it will operate suddenly and injuries or accidents may be caused CAUTION Output Indicator Light Green Overload Indicator Light Red Fuse Low oil alarm Indicato...

Страница 22: ...uipment being used the output indicator light green will go out the overload indicator light red will light continuously and no power will be put out At this time the engine will not stop so that the...

Отзывы: