Possible faults description
Symptoms
Tips
There are no signs of operation
of device despite connection to
the network.
Check if line fuses are not blown, replace if necessary.
Preset boiler temperature on the
display is different from the
required one.
Check:
▪
If in this time the HUW tank is not loaded and if preset temperature is set above the
preset boiler temperature. If so then the difference in readings will disappear after
heating the HW tank or reduce the preset HUW temperature.
▪
If time periods are activated
– then deactivate time periods.
CH pump is not working.
Check:
▪
If boiler exceeded temperature above parameter
CH activating temp.
– wait or reduce
value of this parameter.
▪
If
HUW priority
is activated which blocks CH pump
– deactivate priority be setting
HUW
mode
on
No priority
.
▪
If CH pump is damaged or blocked.
Fan does is not working.
▪
If producer of the boiler has equipped it with temperature limiter STB with manual
return to original position, it should be unlocked by untwisting the cover and twisting
the button according to documentation of boiler producer.
▪
Check the fan and replace it if necessary.
Fuel feeder is not working / does
not provide fuel
▪
Check if feeder wires are correctly connected to terminals.
▪
If temperature limiter STB is connected to terminals 1-2, then check if the circuit is not
cut off due to boiler overheating.
▪
Check if feeder engine is not broken or damaged.
▪
In case when engine work can be heard and fuel is not provided check the feeder with
its user manual.
Fuel is not burnt off completely,
there are not burnt remnants in
ashes. Fuel burns with big
amount of smoke, burner fades
▪
Check settings in the menu:
Output modulation
.
Temperature is not measured
correctly.
▪
Check if there is a good thermos contact between the temperature sensor and
measured surface.
▪
Check if sensor wire not goes too closely to network wire.
▪
Check if sensor is connected to terminal.
▪
Check if sensor is not broken.
In
HUW
pumps
mode
=
SUMMER heaters are hot, boiler
is overheated.
▪
Increase value of parameter
Extending HUW operation time
to cool off the boiler.
HUW pump is not working, even
if HUW container is loaded
▪
Set the parameter
Extending HUW operation time = 0
In hydraulic installation with
mixing valve and servomotor
–
mixer is not opening.
▪
The cause may be HW silo loading when HW priority is activated. Wait until HUW
container loaded or activate the HUW priority.
▪
The cause may be active function SUMMER.
Changes register:
v1.1
–
11-2020 - change of DZT connection in point
12.5.
Содержание ecoMAX360P1-C
Страница 6: ...6 ...
Страница 7: ...USER SETTINGS ecoMAX360P1 C ...
Страница 18: ...18 ...
Страница 19: ...19 INSTALLATION AND SERVICE SETTINGS ecoMAX360P1 C ...
Страница 42: ...42 ...
Страница 43: ...43 ...