HIGH LIMIT CONTROL
Kintera Fryers are equipped with a secondary heat control that prevents the oil temperature from rising
above 450°F. (Because of the accuracy tolerance of the sensor, the oil temperature may reach as high as
475°F.)
In the event the fryer shuts down due to this condition, the oil must be cooled to below 400°F before the pilot
burner can be re-ignited. When the oil has cooled, use the “Lighting” procedure on page 12 to place the fryer
back in operation. If the problem persists, contact your Kintera Service Representative or the Kintera
Service Department.
C
OOKING
H
INTS
USER TIPS
•
Smoking oil means that the temperature is too high, or that the oil has broken down. Time to filter or
replace.
•
Gum in frypot denotes a need for thorough cleaning (see “Weekly Cleaning” on page 15)
•
Use different oil for oily foods (mackerel, nutmeg, etc.) other than for foods with
water-soluble flavors (potatoes, onions, etc.).
•
Taste cool oil for quality. Replace it regularly.
•
Remember, good oil produces good food.
C
LEANING
Kintera equipment is constructed with the best quality materials and is designed to provide durable service
when properly maintained. To expect the best performance, your equipment must be maintained in good
condition and cleaned daily. Naturally, the frequency and extent of cleaning depends on the amount and
degree of usage.
Following daily and more extensive periodic maintenance procedures will increase the life of your
equipment. Climatic conditions (e.g., salt air) may result in the need for more thorough and more frequent
cleaning in order to keep equipment performing at optimal levels.
:
B
URN
H
AZARD
If necessary to move the fryer for cleaning, etc., allow to completely cool, drain the oil first to avoid death
or serious injury.
If disconnection of the restraint is necessary to move the appliance for cleaning, etc., reconnect it when
the appliance is moved to its originally installed position.