13.0 Precautions, Requirements & Exclusions
The integrity of the System is only ensured if the user wears the
recommended personal protective equipment (PPE). This should
be certified and marked in accordance with the relevant national
standard. Using the wrong PPE or lanyards of incorrect length
can result in injury or death. Each system installed should be
supplied with specifications of a full body harness, lanyards and
shock absorbing device. The following precautions, requirements
and exclusions apply to the Kingspan SafePro 2 Cable System:
– The System must be installed by an Certified Kingspan
Installer or competent person trained by the manufacturer or
manufacturer’s representative
– A recorded inspection must be conducted at least once a year
by a Certified Kingspan Installer
– Do not attempt to test systems with dynamic or static
loads. Kingspan Certified Installers carry the appropriate test
equipment for testing the Anchor and fixings
– The System must not be used for lifting
– Do not use the system for equipment tie back
– Never exceed the recommended number of users on the
system (See label on product or system tag)
– Never attempt to repair, tamper with or change the System
– Do not use the system if it appears to be damaged or appears
to have parts missing
– The equipment should not be used outside of its limitations,
nor shall it be used for any other purpose than that intended.
– Each user should weigh no more than the maximum rated
load for the energy absorbing lanyard. The lanyard shall be
capable of limiting the fall arrest load to less than 6 kN
(1350 lbs)
– DO NOT attempt to clean the system with aggressive cleaning
chemicals and abrasive products
– DO NOT use external systems in the event of a electrical storm
– Only personnel trained to work at height and in the correct
operation of the systems should be permitted to use it
– In the unlikely event that a fall does occur the system should
not be used until it has been inspected by a Kingspan certified
Installer
– Do not use the Anchor(s) if it is not clearly labelled
– If the cable is damaged, or if the cable is kinked, don’t use the
system.