9
User Instruction Manual
Kingspan SafePro 2
Anchor and Cable System
Kingspan ExoFit NEX™ Harness
Kingspan SafePro 2 Single Point
Anchor installed on a Standing Seam Roof
6.1 Harnesses and Lanyards
Equipment should be certified and marked to the appropriate
national standard, always refer to the manufacturers
instructions for use. Always wear a full body harness. Examine
harnesses, lanyards, self-retracting lifelines or controlled rate
descent devices in accordance with their manufacturer’s
instructions to ascertain if they are serviceable. If in doubt do not
use them. If these items have been subjected to a fall they must
be serviced or discarded. When not in use these articles need to
be stored in a clean, cool, dry area, free from chemical fumes or
corrosive elements. Direct sunlight, heat, steam, undue vibration
and sharp implements must also be avoided. Preferably, fall
arrest equipment like this should, when not required for use, be
kept in dedicated cabinets which permit adequate ventilation.
6.0 Pre-Use & In Use Checks
6.2 The Anchor
Carry out a visual inspection to check that the Anchor(s)
components have not been subjected to damage between
periods of use.
– Check for any obvious damage such as cracks, heavy
indentations, deformation or severe corrosion.(Deformation
and indentations may be evidence that a fall has occurred
– Check for chemical contamination (e.g. discolouration) and
heat damage, (e.g. weld splatters)
– Check for loose fixings
– Check the maximum number of users
– Check that the Anchor certification is valid
– Check that the anchor has not been deployed
– Check that the ground clearance is still the same as detailed
on installation and that there is no risk of collision in the event
of a fall - including swing fall (pendulum fall) hazards.
If any of the above is questionable do not use the Anchor and
report to a Certified Kingspan Installer.