UNIVERSAL FIREBOX
The ZVF36U, ZVF42U and ZVF52 are approved as a Zero Clearance Universal Firebox.
When installing another manufacturer’s log and burner system, follow the manufacturer’s assembly instructions.
For framing, see page 10 for ZVF36U Firebox or page 11 for ZVF42U Firebox and page 12 for ZVF52 Firebox. Follow all
clearances to combustibles in this manual
When using the optional blower kit (Z33FK) in conjunction with the bottom tray (36VF-106) the two leads from the blower
that attach to the thermodisc must be attached together and the thermodisc can be discarded. See page 35 for wiring.
The fireplace hood is packaged on top of the firebox from the factory. It must be installed on the firebox before operation of the
appliance.
The firebox hood must not be replaced with a hood which may be provided with the decorative type unvented room heater.
USE ONLY KINGSMAN DECORATIVE COMPONENT AND REPLACEMENT PARTS.
Firebox #
Firebox Width Front
Firebox Width Back
Firebox Depth
Firebox Max BTU
ZVF36U
29”
22 1/2”
15”
40,000
ZVF42U
33 3/8”
26 3/8”
15”
40,000
ZVF52
41 1/2”
30 3/8”
17 1/2”
40,000