FRAMING SPECIFICATIONS
ZVF52 FIREPLACE AND FRAMING DIMENSIONS
FIGURE 4 – ZVF52
Framing Clearances to Fireplace:
Bottom – 0” / Sides – 0” to standoffs / Top – 0” to standoffs / Adjacent side wall – 6” / Front of fireplace to ceiling – 41”.
INSTALL GAS LINE
FROM THIS SIDE
20.898”
52.000”
44.0”
FLAME PATTERN
44.375”
5.062
6.250”
20.898”
GAS LINE LOCATED ON
OPPOSITE SIDE AS SHOWN
Minimum
enclosure
height
48.061”
44.500”
20.898”
.500”
Gyprock facing
21.398”
44.389”
62.276”
52.0”
17.558”
52.250”
87.365”
17.558”
Nailing
tabs
44.500”
52.250”
20.898”
Gyproc
k
INSULA
TION