background image

33

Fireplace Part Numbers

ZDV3622N

Fireplace Heater Rated NG, Tempered Glass,

21,000 BTU AT 75% efficient. Approved for

bedroom and mobile home.

ZDV3622LP

Fireplace Heater Rated  LP, Ceramic Glass,

21,000 BTU AT 75% efficient. Approved for

bedroom and mobile home.

FIREPLACE REQUIREMENTS
Grills or CVCK (clean view circulating kit)(Required

for each unit)

Z36CVCK

CVCK(clean view circulating kit) no grill required

Z36GBA

Grill Kit - Classic Builder Antique Brass

Z36GBC

Grill Kit - Classic Builder Chrome

Z36GBP

Grill Kit - Classic Builder Polish Brass

Z1GBL

Grill Kit - Black                                                        

Z36PBL

Decorate Black Panel Grill Kit

LOG SET (Required for each unit)

LOGC50

Log Set Campfire

MQROCK1

Rock Set

MQRSP5

Rock Platform, Support

FIREPLACE ACCESSORIES OPTIONS
Fireplace Surrounds - Trims 

Z36SAB

Surround - Antique Brass      

Z36SCR

Surround - Chrome

Z36SPB

Surround - Polish Brass      

Z36SLAB

Surround Slim Line - Antique Brass                         

Z36SLCR

Surround Slim Line - Chrome  

Z36SLPB

Surround Slim Line - Polish Brass                      

Z36SLBL

Surround Slim Line - Gun Metal Black                      

Designer Doors for 36” Fireplaces - Operative

Z36DDA1BL

Designer Door Arch - Series 1 - Black

Z36DDTA1A

Trim - Antique for Designer Arch - Series 1

Z36DDTA1C

Trim - Chrome for Designer Arch - Series 1

Z36DDTA1P

Trim - Polish Brass for Designer Arch - Series 1

Z36DDS1BL

Designer Door Straight - Series 1 - Black

Z36DDS2BL

Designer Door Straight - Series 2 - Black

Z36DDS3BL

Designer Door Straight - Series 3 - Black

Z36DDTS1A

Trim - Antique for Designer Straight - Series 1

Z36DDTS1C

Trim - Chrome for Designer Straight - Series 1

Z36DDTS1P

Trim - Polish for Designer Straight - Series 1

Child Safety Screens

Z36CSS

Child Safety Screen - 33” DV Fireplaces

Overlays

Z36ADDX

Arch Door Frame - Deluxe Black (352)

Z36ADTH

Arch Door Frame - Top Half Black (353T)

Z36ADDA

Arch Door Frame - Double Arch Black (354)

Z36ADDD

Arch Door Frame - Double Door Arch Black (355)

Z1ADBL

Arch Door Frame Black

Fan Kit/ Blower

Z36FK

Fan Kit w/Variable Speed Wall Mount Control 

(Temperature Sensing)

6000-081

Blower Motor QLN657/1800(Z36FK MOTOR) 

ZDV3622 Parts List

Refractory Liners

Z3622PRL

Porcelain Reflective Liner

Z3622ML

Metal Liner Traditional

Door Glass

3600-311

Tempered Glass - ZDV3622

1000-305

Ceramic Glass - for all ZDV3600

Replacement Burner Assembly

3622-BNGSI

Burner Assembly - Natural Gas c/w Valve

System (ZDV3622N)

3622-BLPSI

Burner Assembly - Liquid Propane c/w Valve

System (ZDV3622LP)

Conversion Kit  (Sit Valve Only)

3622-CKLP

Propane Conversion Kit

3622-CKNG

Natural Gas Conversion Kit

MARQUIS WALL SURROUND COLLECTION
Fireplace Wall Mount Finishing Surrounds for

Z36CVCK  Unit

MQ36SWFBL

Surround Flat Black

(Coverage 37 5/32” H x 50 5/16” W)

MQ36SWFPW

Surround Flat Pewter 

(Coverage 37 5/32” H x 50 5/16” W)

Marquis Wall Surround Accents (Four Pieces)

MQ36SWAKSB

Wall Surround Accents - Keystone Black

MQ36SWAKSC

Wall Surround Accents - Keystone Chrome

MQ36SWABBC

Wall Surround Accents -

Band Black x 4, Chrome x 2

MQ36SWACB

Wall Surround Accents - Corner Black

Содержание Zero Clearance

Страница 1: ...use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to light any appliance Extinguish any open flame Do not touch...

Страница 2: ...hould leave the area during the cure phase Ventilate well open doors and windows Do not touch during curing Why does my fireplace or stove give off odor It is normal for your fireplace to give off som...

Страница 3: ...14 Mantel Leg Clearances 15 Clearance to Combustibles Specifications 16 Dimensions Installation of Wall Mount Surrounds 17 Fan Installation 18 Brick Installation 19 Porcelain Panel Installation Guide...

Страница 4: ...ANUFACTURED MOBILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded to the s...

Страница 5: ...iately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water 12 WARNING Do not operate appliance with t...

Страница 6: ...terminal must be used and if applicable a Product approved air intake must be used Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructi...

Страница 7: ...d installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall c...

Страница 8: ...be raised a minimum of 2 7 8 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplace to the ceilin...

Страница 9: ...9 Z33CVCK Framing and Facing Requirements ZDV3318 WITH Z33CVCK CLEAN VIEW CIRCULATING KIT Z33CVCK with Wall Surround...

Страница 10: ...nd installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall...

Страница 11: ...fireplace must be raised a minimum of 2 1 2 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplac...

Страница 12: ...12 Z36CVCK Framing and Facing Requirements ZDV3622 WITH Z36CVCK CLEAN VIEW CIRCULATING KIT Z36CVCK with Wall Surround...

Страница 13: ...ers skip to Step 4 Using screws provided fasten the non combustible header onto the top of CVCK assembly 4 Hang CVCK onto top of fireplace retainer tabs and rotate into position Fig 2 5 Using 4 suppli...

Страница 14: ...ZDV3318 3622 Mantels Surrounds Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a combu...

Страница 15: ...o or over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top...

Страница 16: ...iance For units with CVCK Clear View Circulating Kit see framing with CVCK to establish floor heights ZDV3622 Clearance to Combustibles Clearance to Combustibles Back from Standoffs 0 inches 0 mm Side...

Страница 17: ...G 8 3 4 8 3 4 H 1 1 I 1 3 16 1 3 16 1 Set Surround Lip on CVCK Ledge and ensure that it is securely in place 2 Swing the upper portion of the Surround so that the Surround Ledge is resting on top of t...

Страница 18: ...o 120v Install a duplex outlet to junction box and plug fan into outlet 4 Turn the wall switch on clockwise Turn fireplace on Once the sensor in the unit reaches operating temperature approximately 10...

Страница 19: ...towards you and lift panel over the burner assembly Fig 2 5 To place side Liner Panels rotate panel towards you and place bottom edge of panel over the front ledge of firebox Fig 3 Rotate panel uprigh...

Страница 20: ...e panel tilt it towards you while lifting it over the burner assembly 5 To place the side liner panels rotate it towards you while placing the bottom edge over the front ledge of the firebox Then rota...

Страница 21: ...proved fittings Always pro vide a union so that gas line can be easily disconnected for burner or fan servic ing See gas specification for pressure details and ratings 4 When a vertical section of gas...

Страница 22: ...pilot screw to provide proper sized flame Caution Do Not Wire 120 Volt PowerTo Millivolt Switches Or Thermostats Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire...

Страница 23: ...amped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove 5 Refer to the Appliance Manufacture...

Страница 24: ...ch If burner comes on replace Switch ON defective wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connec tions are bad Generator may not be ge...

Страница 25: ...4 Locate left side Log 1 locator tab Place Log 1 onto locator tab by aligning placement hole on the underside of Log 1 with tab STEP 5 Locate right side Log 2 locator tab Place Log 2 onto locator tab...

Страница 26: ...ate bar Slide into place and rest Log 5 onto Log 2 s flat area STEP 10 Position Log 6 up against the 2nd grate from the right Log 6 will rest onto Log 2 Do not position over main burner ports STEP 11...

Страница 27: ...fami ly dwellings and serves both dwellings 4 Permitted only if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor 5 Clearance in accordance with local installati...

Страница 28: ...g Kingsman Flex pipe is shipped in unexpanded length When installing pipe expand the lengths Pipe can be expanded to twice their lengths e g 4ft to 8ft Fully expand pipe and cut off excess Do not use...

Страница 29: ...ght of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal verti...

Страница 30: ...assing through a ceiling or floor If an attic insulation shield is to be used a fire stop is not required Roof Flashing Ensure that you have the proper roof flashing by checking your roof pitch using...

Страница 31: ...IR INTAKE ADJUSTMENT PLATE NOTE Unit comes preset for short horizontal or vertical venting under a 15 feet run Follow these instructions when venting exceeds 15 foot run 1 Locate the 3 x 1 4 hex screw...

Страница 32: ...ight Series 3 Black Z33DDTS1A Trim Antique for Designer Straight Series 1 Z33DDTS1C Trim Chrome for Designer Straight Series 1 Z33DDTS1P Trim Polish for Designer Straight Series 1 Child Safety Screens...

Страница 33: ...36DDS3BL Designer Door Straight Series 3 Black Z36DDTS1A Trim Antique for Designer Straight Series 1 Z36DDTS1C Trim Chrome for Designer Straight Series 1 Z36DDTS1P Trim Polish for Designer Straight Se...

Страница 34: ...ece Kit Catalog Number Description ZDVHSK Horizontal Vent Starter Kit 3 FT Length Horizontal Vent Termination Wall Thimble 36 Flex Pipe Mill Pac ZDVHSK5 Horizontal Vent Starter Kit 5 FT Length Horizon...

Страница 35: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Отзывы: