background image

BASIC ONE YEAR WARRANTY

During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials 
or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate
schedule and any repair work must be done through an authorized Kingsman dealer.

LIMITED LIFETIME WARRANTY

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted against 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor in exchange for the replacement part. Any labor, material, freight and/or handling charges associated with any repair 
or replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.

GENERAL TERMS

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit equal 
to the distributors component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given 
in lieu of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit being
replaced must be made available to our distributor for disposition.

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime
Warranty, reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date of
manufacture plus thirty (30) days.

We will not be responsible for and you, the user, will pay for: (a) damages caused by accident, abuse, negligence, misuse, riot, fire, flood,
or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or any other 
damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or repair 
of the unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's components
(e) damages caused by failing to provide proper maintenance and service to the unit (f) any expenses incurred for erecting, disconnecting 
or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, inoperation or inefficiency
resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel cost whatsoever including 
additional or unusual use of supplemental electric heat.

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this unit. 
We have not made and do not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition
of fitness for a particular use or purpose. We make no express warranties except as stated in this Limited Lifetime Warranty. No one is authorized
to change this Limited Lifetime Warranty or to create for us any other obligation or liability in connections with this unit. Any implied 
warranties shall last for one year after the original installation. Some states and provinces do not allow the exclusion or limitation of incidental 
or consequential damages or do not allow limitations on how long an implied warranty or condition lasts, so the above limitations or exclu-
sions may not apply to you. The provisions of this limited warranty are in additions to and not a modification of or subtraction from any statu-
tory warranties and other rights and remedies provided by law.

Save this certificate. It gives you specific legal rights, and you may also have other rights which may vary from state to state and province to province.

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available for support
and we, in turn support the distributor's efforts.

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your files.

Model No.

Serial No.

Date installed

Dealer or Contractor Name :

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit.

LIMITED LIFETIME WARRANTY

This Limited Lifetime Warranty applies only while the unit remains at the site of the original
installation and only if the unit is installed inside the continental United States, Alaska, Hawaii,
and Canada. The warranty applies only if the unit is installed and operated in accordance 
with the printed instructions and in compliance with applicable installation and building codes 
and good trade practices.

The Ultimate in Design, Engineering & Quality

Содержание Zero Clearance

Страница 1: ...use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What To Do If You Smell Gas Do not try to light any appliance Extinguish any open flame Do not touch...

Страница 2: ...hould leave the area during the cure phase Ventilate well open doors and windows Do not touch during curing Why does my fireplace or stove give off odor It is normal for your fireplace to give off som...

Страница 3: ...14 Mantel Leg Clearances 15 Clearance to Combustibles Specifications 16 Dimensions Installation of Wall Mount Surrounds 17 Fan Installation 18 Brick Installation 19 Porcelain Panel Installation Guide...

Страница 4: ...ANUFACTURED MOBILE HOMES Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded to the s...

Страница 5: ...iately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water 12 WARNING Do not operate appliance with t...

Страница 6: ...terminal must be used and if applicable a Product approved air intake must be used Installation shall be in strict compliance with the manufacturer s instructions A copy of the installation instructi...

Страница 7: ...d installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall c...

Страница 8: ...be raised a minimum of 2 7 8 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplace to the ceilin...

Страница 9: ...9 Z33CVCK Framing and Facing Requirements ZDV3318 WITH Z33CVCK CLEAN VIEW CIRCULATING KIT Z33CVCK with Wall Surround...

Страница 10: ...nd installation with a top vent is possible as long as the hori zontal portion of the vent system does not exceed 20 feet 6 1 m A Flat on a wall D As a room divider B Across the corner E Flat on wall...

Страница 11: ...fireplace must be raised a minimum of 2 1 2 above the finished floors to accommodate the wall surround The fireplace may be raised higher but the 60 clearance measured from the bottom of the fireplac...

Страница 12: ...12 Z36CVCK Framing and Facing Requirements ZDV3622 WITH Z36CVCK CLEAN VIEW CIRCULATING KIT Z36CVCK with Wall Surround...

Страница 13: ...ers skip to Step 4 Using screws provided fasten the non combustible header onto the top of CVCK assembly 4 Hang CVCK onto top of fireplace retainer tabs and rotate into position Fig 2 5 Using 4 suppli...

Страница 14: ...ZDV3318 3622 Mantels Surrounds Warning Combustible objects must not be placed on a non combustible mantel unless the non combustible mantel meets the minimum height and width requirements for a combu...

Страница 15: ...o or over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top...

Страница 16: ...iance For units with CVCK Clear View Circulating Kit see framing with CVCK to establish floor heights ZDV3622 Clearance to Combustibles Clearance to Combustibles Back from Standoffs 0 inches 0 mm Side...

Страница 17: ...G 8 3 4 8 3 4 H 1 1 I 1 3 16 1 3 16 1 Set Surround Lip on CVCK Ledge and ensure that it is securely in place 2 Swing the upper portion of the Surround so that the Surround Ledge is resting on top of t...

Страница 18: ...o 120v Install a duplex outlet to junction box and plug fan into outlet 4 Turn the wall switch on clockwise Turn fireplace on Once the sensor in the unit reaches operating temperature approximately 10...

Страница 19: ...towards you and lift panel over the burner assembly Fig 2 5 To place side Liner Panels rotate panel towards you and place bottom edge of panel over the front ledge of firebox Fig 3 Rotate panel uprigh...

Страница 20: ...e panel tilt it towards you while lifting it over the burner assembly 5 To place the side liner panels rotate it towards you while placing the bottom edge over the front ledge of the firebox Then rota...

Страница 21: ...proved fittings Always pro vide a union so that gas line can be easily disconnected for burner or fan servic ing See gas specification for pressure details and ratings 4 When a vertical section of gas...

Страница 22: ...pilot screw to provide proper sized flame Caution Do Not Wire 120 Volt PowerTo Millivolt Switches Or Thermostats Recommended Maximum Lead Length Double Wire When Using Wall Switch or Thermostat Wire...

Страница 23: ...amped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove 5 Refer to the Appliance Manufacture...

Страница 24: ...ch If burner comes on replace Switch ON defective wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connec tions are bad Generator may not be ge...

Страница 25: ...4 Locate left side Log 1 locator tab Place Log 1 onto locator tab by aligning placement hole on the underside of Log 1 with tab STEP 5 Locate right side Log 2 locator tab Place Log 2 onto locator tab...

Страница 26: ...ate bar Slide into place and rest Log 5 onto Log 2 s flat area STEP 10 Position Log 6 up against the 2nd grate from the right Log 6 will rest onto Log 2 Do not position over main burner ports STEP 11...

Страница 27: ...fami ly dwellings and serves both dwellings 4 Permitted only if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor 5 Clearance in accordance with local installati...

Страница 28: ...g Kingsman Flex pipe is shipped in unexpanded length When installing pipe expand the lengths Pipe can be expanded to twice their lengths e g 4ft to 8ft Fully expand pipe and cut off excess Do not use...

Страница 29: ...ght of the system and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal verti...

Страница 30: ...assing through a ceiling or floor If an attic insulation shield is to be used a fire stop is not required Roof Flashing Ensure that you have the proper roof flashing by checking your roof pitch using...

Страница 31: ...IR INTAKE ADJUSTMENT PLATE NOTE Unit comes preset for short horizontal or vertical venting under a 15 feet run Follow these instructions when venting exceeds 15 foot run 1 Locate the 3 x 1 4 hex screw...

Страница 32: ...ight Series 3 Black Z33DDTS1A Trim Antique for Designer Straight Series 1 Z33DDTS1C Trim Chrome for Designer Straight Series 1 Z33DDTS1P Trim Polish for Designer Straight Series 1 Child Safety Screens...

Страница 33: ...36DDS3BL Designer Door Straight Series 3 Black Z36DDTS1A Trim Antique for Designer Straight Series 1 Z36DDTS1C Trim Chrome for Designer Straight Series 1 Z36DDTS1P Trim Polish for Designer Straight Se...

Страница 34: ...ece Kit Catalog Number Description ZDVHSK Horizontal Vent Starter Kit 3 FT Length Horizontal Vent Termination Wall Thimble 36 Flex Pipe Mill Pac ZDVHSK5 Horizontal Vent Starter Kit 5 FT Length Horizon...

Страница 35: ...service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoeve...

Отзывы: