17
Fan Kit Installation for Fan Assembly Z36FK
Fan Mounting Instructions
1. Install Thermodisc provided with Fan kit. Screws and washer spac-
ers are Factory installed in bottom of firebox. Washer spacers are to
be placed in between firebox and thermodisc.
2. (NEW STYLE MOUNTING SYSTEM). The bottom of the unit
has 2 tabs prepunched (bent upwards) for the rubber grommets in
fan bracket. Place fan bracket over tabs. This will secure the fan.
3. Junction box should be mounted to opposite side and wired to vari-
able speed control and 120v power.
4. Plug fan into junction box and attach the 2 leads exiting the fan
housing into the thermodisc.
5. Close lower access cover.
6. Turn the wall switch on (clockwise). Turn the fireplace on. Once the
sensor unit reaches operating temperature in approximately 10 to 15
minutes the fan will turn on. The fan can be switched off, if desired,
by turning the wall switch fully counter-clockwise.
7. To set the minimum fan speed, if desired, remove the variable speed
switch from the wall mount. Turn the variable speed wall controller
to its minimum setting (fully clockwise). Use the set screw on the
side of the variable speed controller to increase or decrease the
minimum fan speed. (It may be desirable to lower minimum fan
speed to decrease the sound level created by the fan.) Reinstall
switch into wall mount and cover with face plate.
Parts List:
1 ea. fan comes with 4 ft cord. Two 14’ leads (female ends)
2 ea #8 x 1/2” screws
1 ea variable speed control (wall mount type)
1 ea thermodisc
Electrical Services
All optional fan kits are equipped with a 120V, 60Hz blower.
Note: All electric connections are to be made in accordance with CSA
Standard C22.1 - Canadian Electrical Code part I or with the National
Electrical Code, ANSI/NFPA 70 (latest edition) and/or in accordance
with local codes.
WARNING: Electrical Grounding Instructions. This appliance
is equipped with a three-pronged (grounding) plug for your
protection against shock hazard and should be plugged directly
into a properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
Caution: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation.
Verify proper operation after servicing.
Caution:
Should this fan require
servicing, the power supply
must be disconnected.