Approved for Power Vent PVH58 / PVH58FM
- This appliance is approved for use with Kingsman Horizontal Power Vents -
A Horizontal Power Vent Termination is intended for use where standard venting configurations are not
possible.
NOTE:
MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are
NOT
permitted.
NOTE:
MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION (Proflame 1 or Proflame 2): Downward
vertical vent runs are permitted, however, Cold Climate Switch (Standing Pilot Mode) must
NOT
be used.
ENCLAVE & SERENE Units - Maximum & Minimum
Vent Lengths using Power Vents:
Minimum Vent Length
is 4 FT vertical x 6 FT
horizontal with up to 5 elbows.
Maximum Vent Length is 4FT vertical x 125FT
horizontal with up to 7 elbows.
Refer to Power Vent Manual for proper installation
and use.
ENCLAVE & SERENE Units – Can be Reduced to 3 x 5”
or 4 x 6-5/8” Venting
(A 12 Inch Length of 5/8 M&G Duravent Pipe Must be
Connected to Fireplace Flue First.)
3 x 5” Venting:
-
PVA5835
- Pipe Reducer for
Fireplace
-
PVA3558
- Pipe Increaser for
Termination
4 x 6-5/8” Venting:
-
ZDVDRA
- Pipe Reducer for
Fireplace
-
ZDVDIA
- Pipe Increaser for
Termination
PVH58
PVH58FM
At Fireplace Flue:
PVA5835 for 3 x 5” Venting
ZDVDRA for 4 x 6-5/8” Venting
For Power Vent Termination:
PVA3558 for 3 x 5” Venting
ZDVDIA for 4 x 6-5/8” Venting
ZDVDRA
5/8
M & G
DURAVENT
PIPE
12”
80
Содержание ZCVRB47