ZCVRB47- Framing Dimensions –Unvented Chase-Ventilation Plates In Place- As Shipped
Determine whether face of fireplace will be:
Flush with finished wall (e.g., for surround, cultured stone or other non combustible covering).
Flush with framing (to be covered with concrete board for a Flat Wall appearance).
Refer to Nailing Tab Guide section also.
38-3/4”
HEADER
52” MIN
Plus Rise of 1/4”
Per Foot
34-5/8”
To Face
Framing
MIN 70”
Ceiling &
Enclosure
MIN 70”
Ceiling &
Enclosure
Fig.1
Framing for Horizontal Vent
Termination
(See
Installation of Side
Wall Venting
Section)
Vertical Venting MUST maintain 1” clearance to combustibles.
These structures are not
load bearing.
Note: If using optional surround, maximum thickness for non-combustible material is 1-1/8”.
Fig. 1
Shown flush
with framing.
TV
Optional
Recess
Variable