Locating Your Appliance
Note:
Ventilation and air flow comes from openings in the walls and ceiling. Open floor space around the appliance
must not be considered ventilation and air flow space.
This unit requires combustion air and will produce exhaust gases. Install in an open-air situation with natural
ventilation and without stagnant areas.
Avoid installing in tight spaces and corners.
Be aware of combustibles (i.e. furniture) near appliance. Clearance is Minimum 36”.
By definition, an outdoor space is not enclosed. Any area in which these appliances are used shall comply with
the structures shown below.
Locating Your Appliance – Outdoor Spaces
This appliance may be installed within the following structures:
1.
Walls on all sides (Minimum area of 96 square feet), but
with no overhead cover and at least one permanent
opening (doorway) at ground level.
2.
Within a partial enclosure that includes an overhead cover
and no more than two side walls.
3.
These side walls may be parallel, as in a breezeway, or at
right angles to each other.
4.
Within a partial enclosure that includes an overhead cover
and three side walls, as long as
30 percent
or more of the
horizontal periphery of the enclosure is permanently open.
All models can be installed safely in a screened porch area within the following guidelines:
Minimum porch area is 96sq. feet with one side fully open.
A minimum of two (2) walls can be screened, but must be open to outside ventilation, with a minimum screen area of 64
sq. feet, and a minimum side wall height of 78” inches.