20lb Cylinder Installation - Fire Table - Custom Installations
Fire Tables -20LB Cylinder In Unit-
⚠
Only a 20LB LP Cylinder may be used inside the Fire Table Enclosure.
NOTE:
Cylinders acceptable for use inside this appliance must be compatible with the retention means shown here.
The LP gas supply cylinder used with LP models
must be constructed and marked in accordance
with the specifications for LP-gas cylinders of the
U.S. Department of Transportation (DOT)
Specifications for LP-Gas Cylinders, or the
Standard for Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods and
Commission
, CAN/CSA-B339, as applicable.
The LP gas supply cylinder used with LP models
must be provided with a listed overfilling
prevention device.
The pressure regulator and hose assembly
supplied with LP models (PN#
27FP-900FF
) must
be used. Replacement pressure regulators and
hose assemblies must be those specified in this
manual.
Always check for gas leaks with a soap and water
solution. DO NOT USE OPEN FLAME FOR LEAK
TESTING.
When an LP model is not in use, the LP-gas must
be turned off at the supply cylinder.
CUSTOM INSTALLATIONS
TANK RETAINER - Included with all MAP Burners and LP
Conversion Kits
1. Connect foot ring of 20lb
Cylinder to Tank Retainer with
thumbscrew.
2. Fasten Tank Retainer to
mounting surface.
3. Concrete anchor
required for concrete
surface (not supplied).
Foot Ring Drops
into Round Hole
Replace
Tank Brace
.
Slide over Protective
Collar of 20lb cylinder
and tighten.
Tank Retainer for Custom
Installations.
NOT USED ON FIRE TABLES.
Installation of 20lb Cylinder
into Fire Tables:
Remove Top Clamp.
Connect 20lb cylinder to
regulator.
Place 20lb cylinder into
Fire Table as shown.
Secure 20lb cylinder with
Tank Brace as shown.
Tank Brace
23