background image

Fire Tables    

 

-Assembly- 

OUTDOOR FIRE TABLES: 

OLTN24, OLTW24, OLTN36, OLTW36, OLTN48, OLTW48 

Tools Required:

 1/4” Hex Driver c/w 4” Extension or 1/4” Hex Screwdriver 

NOTE: Two people are required to lift this assembly.

 

 

Step One:

 Lay Table Top upside down on a flat non-

abrasive surface. 

 

Step Two:

 Form Tank Shield into shape and attach to 

one end of Table Top with [4] DT Screws. 

NOTE: There 

will be two Tank Shields for 36” and 48” models.

 

 

Step Three:

 

Carefully 

place Table 

Body onto 

Table Top 

and attach 

with [4 or 6] 

bolts.  

NOTE: Tank 

Brace & 

Tank Shield 

must be on 

the same 

side as the 

Tank Mount Hole.

 

 

Step Four:

 Install Tank 

Brace with Washer and 

Thumbscrew.  

Carefully lift and place 

Fire Table upright. 

Install Doors using [2] 

DT Screws each. 

NOTE: Doors may be 

installed on either left 

or right side.

 

Burner Lid 

Tank Shield 

Table Top 

Table Top 

Table Body 

Tank 

Mount 

Hole 

Tank 

Guard 

Table Top 

Table Top 

Outer Trim Ring

 

Table Top

 

Table Body

 

Tank Shield

 

Door

 

Door

 

Parts List: 

BOX 1: 

[1ea.] Burner Lid  

 [1ea.] Outer Trim Ring  

[1ea.] Table Top  

[1ea.] Tank Shield, [2ea.] for 36” & 48” 

BOX 2: 

[1 ea.] Table Body  

[2 ea.] Door  

[1 ea.] Tank Brace 

Hardware: 

[8 ea.] DT Screws, [12ea.] for 36” & 48” 

[4 ea.] Bolts 8-32 x 1”, [6ea.] for 36” & 48” 

Tank 

Brace 

Tank Brace

 

Tank 

Shield 

20

Содержание OB24MAN

Страница 1: ...d liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING For Outdoor Use Only WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servic...

Страница 2: ...sive abrasion or wear or the hose is damaged it must be replaced prior to the appliance being put into operation Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage 7 Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage 8 Children and adults should be ale...

Страница 3: ...ing 22 Outdoor Fire Tables 20lb Cylinder Installation 23 OUTDOOR FIREPLACES Outdoor Fireplaces OFP OFP4336S1 OFP4336S2 Dimensions 24 Outdoor Fireplaces OFP OFP5548S1 OFP5548S2 Dimensions 25 Outdoor Fireplaces OFP OFP7972S1 OFP7972S2 Dimensions 26 Outdoor Fireplaces OFP Handling Unit 27 Adjustable Support Guide Hearth Flush With Fireplace Opening 28 Outdoor Fireplace OFP Optional Framing S1 S2 29 O...

Страница 4: ...l as the appliance heats up and cools down This is normal and is similar to the sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace Note to the Installer Be sure appliance is working properly and its operation including remote control operation if included is fully explained to and understood by the customer Important Information Abo...

Страница 5: ...y be installed within the following structures 1 Walls on all sides Minimum area of 96 square feet but with no overhead cover and at least one permanent opening doorway at ground level 2 Within a partial enclosure that includes an overhead cover and no more than two side walls 3 These side walls may be parallel as in a breezeway or at right angles to each other 4 Within a partial enclosure that in...

Страница 6: ...to be installed above a gas meter regulator assembly within 3ft horizontally from the center line of the regulator Not allowed Vinyl NOTE Diagrams Illustrations not to scale A fireplace shall not open directly above a sidewalk or paved driveway which is located between two single family dwellings and services both swellings Only permitted if veranda porch deck or balcony is fully open on a minimum...

Страница 7: ...r Fire Stand is available with a Manual Valve only OB24 OFS24 OB36 OFS36 OB48 OFS48 Outdoor Fire Tables OLTN OLTW Approved Accessory Burner is ordered separately LISTED BURNER OFT Outdoor Fire Table MAP Manual LP MAN Manual NG MVP Millivolt LP MVN Millivolt NG Outdoor Fire Table OB24 OLTN24 Conversion Kit Required OB24 OLTW24 Conversion Kit Required OB36 OLTN36 Conversion Kit Required OB36 OLTW36 ...

Страница 8: ...r c w NG Orifice 7 1 2 wide x 50 long x 2 tall OFS48MAP OLTN48 OLTW48 N A OB48MAN Dante Manual NG Burner For LP order 36 48OB CKLP5 or 36 48OB CKLP10 7 1 2 wide x 50 long x 2 tall OFS48MAN OLTN48 OLTW48 N A OB48MVN SIT Millivolt NG Burner For LP order 48OB CKLP 7 1 2 wide x 50 long x 2 tall N A OLTN48 OLTW48 OFP5548S1 OFP5548S2 OB72MVN SIT Millivolt NG Burner For LP order 72OB CKLP 7 1 2 wide x 74...

Страница 9: ...d Burners with Label Dimensions OB24 OB36 OB48 OB72 OB96 Outdoor Burners OB24 BURNER OB36 BURNER OB48 BURNER OB72 BURNER OB96 BURNER END VIEW ALL BURNERS 2 1 16 2 5 16 38 2 5 16 2 1 16 50 2 5 16 2 5 16 2 5 16 9 ...

Страница 10: ...burner Parts List OB24 OB36 OB48 MAP MAN 1 Burner c w 1 Pilot Shield 2 Ends 3 Filler Strips 1 Manual Valve System c w Regulator and 5ft Hose for LP Systems 1 Push Button Igniter c w wire and Sparker 1 Valve Key 1 Key Way Installation Tool 1 Brass Orifice for NG Conversion LP Systems 1 Tank Retainer LP Systems 1 Hardware Bag 8 1 2 DT Screws 4 6 Black Screws 2 10 Woodscrews 3 Filler Strips See Below...

Страница 11: ...d Sparker 1 On Off Rocker Switch installed on valve 1 Pilot Opening Cover 1 Hardware Bag 12 1 2 DT Screws 8 6 Black Screws 2 10 24 x 1 2 Bolts c w Star Nuts 6 Filler Strips 1 Cover Clip 24OB 23 9 16 36OB 35 9 16 x 2 for OB72 48OB 47 9 16 x 2 for OB96 24OB 10 5 8 36OB 10 5 8 x 2 for OB72 48OB 10 5 8 x 2 for OB96 24OB 10 5 8 36OB 22 5 8 x 2 for OB72 48OB 34 5 8 x 2 for OB96 Connect Electrode Wire to...

Страница 12: ...rs OB24 5 3 4 x 24 1 2 OB36 5 3 4 x 36 1 2 OB48 5 3 4 x 48 1 2 OB72 5 3 4 x 72 1 2 OB96 5 3 4 x 96 1 2 Burners may be connected together in any combination When connecting additional burners add desired lengths 24 36 48 72 96 plus Required Opening for total opening e g 24 72 1 2 24 120 1 2 NOTE Flame height will be noticeably higher on OB48 burners This can be manually adjusted Remove ends when co...

Страница 13: ...a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this The fireplace receptacle must be connected to an external GFI protected outlet installed near the fireplace Before Servicing 1 Ensure all power supply is shut off 2 Label all wires prior to disconnect...

Страница 14: ...n access to the cylinder valves is acceptable provided it is non locking and can be opened without the use of tools Designs using a cover to gain access to the cylinder and cylinder valve shall be provided with handles or equivalent at a minimum of 180 degrees apart to facilitate lifting of the cover The enclosure for the LP gas cylinder shall isolate the cylinder from the burner compartment to pr...

Страница 15: ...Fire Stands Approved Accessory OFS Series Dimensions Outdoor Fire Stand OFS24MAP OFS24MAN OFS36MAP OFS36MAN OFS48MAP OFS48MAN 15 ...

Страница 16: ...ass Orifice for NG Gas Conversion LP Systems 1 Tank Retainer 2ea Wood Screws LP Systems OFS24 Shown Ready for Media Placement See Media Section of Manual for Options END VIEW Outdoor Fire Stand FILLER STRIPS 24OB 23 9 16 36OB 35 9 16 48OB 47 9 16 ALL UNITS 10 5 8 24OB 10 5 8 36OB 22 5 8 48OB 34 5 8 OFP Bottom View MAP System Shown INCLUDED WITH MAP PROPANE BURNER SYSTEMS ONLY Long Flange at Top Sh...

Страница 17: ...ions Outdoor Fire Table OLTN24 BURNER OPTIONS OB24MAP c w 40 Orifice for NG OB24MAN Order 24OB CKLP5 for LP OB24MVN Order 24OB CKLP for LP OLTW24 BURNER OPTIONS OB24MAP c w 40 Orifice for NG OB24MAN Order 24OB CKLP5 for LP OB24MVN Order 24OB CKLP for LP 17 ...

Страница 18: ...s Outdoor Fire Table OLTN36 BURNER OPTIONS OB36MAP c w 31 Orifice for NG OB36MAN Order 36 48OB CKLP5 for LP OB36MVN Order 36OB CKLP for LP OLTW36 BURNER OPTIONS OB36MAP c w 31 Orifice for NG OB36MAN Order 36 48OB CKLP5 for LP OB36MVN Order 36OB CKLP for LP 18 ...

Страница 19: ...s Outdoor Fire Table OLTN48 BURNER OPTIONS OB48MAP c w 30 Orifice for NG OB48MAN Order 36 48OB CKLP5 for LP OB48MVN Order 48OB CKLP for LP OLTW48 BURNER OPTIONS OB48MAP c w 30 Orifice for NG OB48MAN Order 36 48OB CKLP5 for LP OB48MVN Order 48OB CKLP for LP 19 ...

Страница 20: ...4 or 6 bolts NOTE Tank Brace Tank Shield must be on the same side as the Tank Mount Hole Step Four Install Tank Brace with Washer and Thumbscrew Carefully lift and place Fire Table upright Install Doors using 2 DT Screws each NOTE Doors may be installed on either left or right side Burner Lid Tank Shield Table Top Table Top Table Body Tank Mount Hole Tank Guard Table Top Outer Trim Ring Table Top ...

Страница 21: ...NAL ELECTRONIC SPARK ASSIST OB Burner and Valve Assembly Valve Mount Bracket Valve Mount Plate DT Screw DT Screw DT Screw DT Screw 6 Black Screws 6 Black Screws Push Button Igniter Location Valve Key storage on inside of door ON OFF Switch Location Electronic Spark Module 4 DT Screws to attach Valve to Appliance See Electronic Spark Assist Page Piezo Igniter On Off Switch 21 ...

Страница 22: ...our protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this The fireplace receptacle must be connected to an external GFI protected outlet installed near the fireplace Before Servicing 1 Ensure all power supply is shut off 2 Label all wires prior to disconnecting when servicing control Wiring ...

Страница 23: ...bly supplied with LP models PN 27FP 900FF must be used Replacement pressure regulators and hose assemblies must be those specified in this manual Always check for gas leaks with a soap and water solution DO NOT USE OPEN FLAME FOR LEAK TESTING When an LP model is not in use the LP gas must be turned off at the supply cylinder CUSTOM INSTALLATIONS TANK RETAINER Included with all MAP Burners and LP C...

Страница 24: ...laces OFP4336S1 and OFP4336S2 Dimensions Outdoor Fire Place OFP4336S1 Millivolt Natural Gas Convert to LP with Conversion Kit 36OB CKLP OFP4336S2 Millivolt Natural Gas Convert to LP with Conversion Kit 36OB CKLP 24 ...

Страница 25: ...laces OFP5548S1 and OFP5548S2 Dimensions Outdoor Fire Place OFP5548S1 Millivolt Natural Gas Convert to LP with Conversion Kit 48OB CKLP OFP5548S2 Millivolt Natural Gas Convert to LP with Conversion Kit 48OB CKLP 25 ...

Страница 26: ...laces OFP7972S1 and OFP7972S2 Dimensions Outdoor Fire Place OFP7972S1 Millivolt Natural Gas Convert to LP with Conversion Kit 72OB CKLP OFP7972S2 Millivolt Natural Gas Convert to LP with Conversion Kit 72OB CKLP 26 ...

Страница 27: ...MELY HEAVY Ensure that fireplace is properly supported when handling Tab cutouts on the faces of the appliance can be used to assist with handling and locating fireplace Cutouts are for Hand use or 2 x 4 use Lift Tabs are for crane use 2 x 4 2 x 4 Lift Here Lift Here Lift Here 27 ...

Страница 28: ... the fireplace can be used to assist installation NOTE Support Guide is NOT load bearing Bottom of fireplace MUST be supported Set Support Guides at desired height and attach with DT Screws Support Guide Support Guide Set to desired height Ledge Stone Base Support Guide Support Guide Base Bottom of fireplace must be supported 28 ...

Страница 29: ... Non Combustible Facing 1 2 Plywood Exterior Facing Fold Nailing Tabs back onto framing Fold Nailing Tabs back onto framing SIDE OF UNIT RIGHT SIDE OF UNIT Back of Unit Install Non combustible Header Panel Fold Standoffs into position and fasten in place with Screws Use Nailing Tabs to fasten Unit to framing Use Nailing Tabs to fasten Unit to framing 29 ...

Страница 30: ...es In Front of Unit 36 Face or Facing of Fireplace Top Sides and Back of Appliance 0 Standoffs ALCOVE Alcove Depth All Units 36 Face or Facing of Fireplace Alcove Width OFP4336S1 S2 60 Fireplace Opening 43 plus Side wall Dim A 8 1 2 x 2 Alcove Width OFP5548S1 S2 72 Fireplace Opening 55 plus Side wall Dim A 8 1 2 x 2 Alcove Width OFP7972S1 S2 96 Fireplace Opening 79 plus Side wall Dim A 8 1 2 x 2 A...

Страница 31: ...55SS OFP79SS STEP 1 Place bottom of Side Filler into gap at corner of opening STEP 2 Push Side Filler into place Repeat procedure for other side STEP 3 Hook Surround Frame onto Lower Edge of fireplace opening STEP 4 Push Surround Frame into place and attach with screws into top lip of opening LEFT RIGHT RIGHT TOP RIGHT CORNER SCREW HOOK ONTO LOWER EDGE 31 ...

Страница 32: ...ER CAN BE USED WITH OR WITHOUT SURROUND STEP 1 Insert left side of Weather Cover into fireplace opening STEP 2 Insert right side of Weather Cover into fireplace opening Slide to the right until gap is closed Weather Cover is installed 16 1 16 44 for OFP36WC 56 for OFP48WC 80 for OFP72WC 32 ...

Страница 33: ...ents such as the warm highly humid atmosphere around pools and hot tubs These stains could be perceived as rust but can be easily removed or prevented To provide stain prevention and removal wash all stainless steel surfaces every 3 4 weeks or as often as required with fresh water and or stainless steel cleaner Notes on Cleaning Stainless Steel Surfaces Do not use abrasive cleaners or steel wool o...

Страница 34: ...n against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this The fireplace receptacle must be connected to an external GFI protected outlet installed near the fireplace Before Servicing 1 Ensure all power supply is shut off 2 Label all wires prior to disconnecting when servicing control Wiring errors can ca...

Страница 35: ...To remove burner 1 Disconnect gas supply Caution only a qualified person should do this 2 Remove Access Cover 3 Remove Screws in Burner Tray and Valve Bracket TO INSTALL BURNER REVERSE ABOVE STEPS ACCESS COVER VALVE LOCATION Remove Screws in Burner Tray BURNER AND VALVE ASSEMBLY Remove Screws from Valve Bracket 35 ...

Страница 36: ...5 lbs MQG5C Glass Media 1 2 Bronze 5 lbs MQG5W Glass Media 1 2 White 5lbs Use of any other glass can alter the performance of the unit and is not covered under warranty Discoloration of glass media may occur if placed on the burner this is not covered under warranty Optional Media Accessories MQRBD3 Driftwood Log Set 5 piece Place Logs Randomly as shown Do not cover Pilot MQRBD4 Driftwood Log Set ...

Страница 37: ...orative Stones 80 Piece Set MQSTONE10 Decorative Stones 10 Piece Set Place Rocks and Stones randomly Do not cover Pilot Not all Rocks or Stones will be used on all models RBCB1 Canonballs Assorted Size and colors 14 pieces Place Canonballs randomly Do not cover Pilot Not all Canonballs will be used on all models 37 ...

Страница 38: ...anels O24WG 24 Wind Guard O36WG 36 Wind Guard O48WG 48 Wind Guard O72WG 72 Wind Guard O96WG 96 Wind Guard Wind can greatly affect flame performance If used in windy conditions a wind guard is recommended NOTE Painted finishes damaged or discolored by heat are not covered under warranty Corner Bracket c w Neoprene Screws Bottom Foot Glass Side Panel Glass End Panel 38 ...

Страница 39: ...ing pilot system even if the main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the unit at least once a month and inspect the flame pattern to ensure there are no problems with the burner tube Flame should appear similar to the above picture The pilot flam...

Страница 40: ...ust have threaded valve plugs tightly installed and must not be stored in a building garage or any other enclosed area Storage of this appliance indoors is permissible only if it has been disconnected from its fuel supply natural gas line or LP gas cylinder The LP gas cylinder supply system must be arranged for vapor withdraws The LP gas cylinder used must include a collar to protect the cylinder ...

Страница 41: ... gas control valve 4 Place a burning match on top of burner in the middle where ports are present DO NOT HOLD THE MATCH IN HAND For Natural Gas unit turn on the on off valve slowly at the unit For LP unit turn the valve on the LP tank counterclockwise all the way and then turn on the on off valve slowly at the unit 5 If the burner does not light before the match goes out immediately turn the gas t...

Страница 42: ... rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter button every 5 seconds until a flame is established NOTE If after 30 seconds a flame has not yet been established then turn the control knob back to the off position and repeat steps 5 6 7 9 Once the pil...

Страница 43: ...Note The gas line connection may be made of 1 2 rigid pipe 1 2 copper pipe or an approved flex connector Since some municipalities have additional local codes it is always best to consult your local authorities and the current CAN CGA B149 1 or 2 installation code in Canada or the National Fuel Gas code ANSI Z223 1 in the U S A MAP MAN MANUAL VALVE DANTE MVN MVP MILLIVOLT VALVE Models OB24MAN OB24...

Страница 44: ...ns for input rates Refer to Lighting Instructions for normal sequence of the ignition system TANK RETAINER Included with all MAP Burners and LP Conversion Kits 1 Connect foot ring of LP Tank to Tank Retainer with thumbscrew 2 Fasten Tank retainer to mounting surface with lag screw 3 Concrete anchor required for concrete surface not supplied LP Conversion Kits for Millivolt and Manual Systems Kit N...

Страница 45: ...ifice into Air Shutter 5 Re attach Orifice Retainer Bracket to Burner Tray 6 Connect LP Hose and Regulator to Valve Assembly WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the Authority Having jurisdiction If the information on in these instructions is not followed exactly ...

Страница 46: ...on Kit also see Parts B C of Conversion Kit Instructions WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the Authority Having jurisdiction If the information on in these instructions is not followed exactly a fire explosion or production of carbon monoxide may result causing...

Страница 47: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove e Refer to the Appliance Manufacturers instruction sheet for the proper injector size 6 Insert the Allen wrench into the end of the injector Then insert into injector j...

Страница 48: ...Gas Conversion for Modulator PART C 48 ...

Страница 49: ...Battery powered module is available to assist in lighting the pilot burner See below for installation Battery Igniter OLTN OLTW Top View OFP Top View OLTN OLTW Ignition Switch Ignition Switch Battery Igniter Ignition Switch Battery Igniter Ignition Switch Battery Igniter OFP 49 ...

Страница 50: ...ve Check wall switch and wires for proper connections Jumper wire across terminals at wall switch If burner comes on replace defective wall switch If okay jumper wire across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be generating sufficient voltage Check generator with millivolt meter Take reading at generator terminals of gas valve Sho...

Страница 51: ...V P16FF 3 8 Stainless Steel Flex Connector 16 Long 3 24OB 102 Orifice Retainer Bracket 4 27FP P904FF 3 8 Tube OD x 1 8 MPT 5 1000 225 Brass Orifice NG or LP Specify size Refer to Chart in Manual 6 26IDV P324A Pilot Tube with Fittings 7 3632HB P496C x2 Brass Elbow 3 8 Tube to 3 8 NPT 8 24OB 109 Valve Bracket 9 1001 P640si Millivolt Valve NG Hi Lo 10 1000 214 Piezo Igniter 11 36HB 115 Piezo Bracket ...

Страница 52: ...etainer Bracket 10 Hose Regulator GLASS MEDIA 5 lbs per Foot of Burner i e 24 burner 10lbs MQG5ZG Glass Media ZIRCON Glacier Ice 5 lbs MQG5A Glass Media 1 2 Cobalt Blue 5 lbs MQG5B Glass Media 1 2 Black 5 lbs MQG5C Glass Media 1 2 Bronze 5 lbs MQG5W Glass Media 1 2 White 5lbs ROCKS AND LOGS MQRBD3 Drift Wood Log Set 5 pcs MQRBD4 Drift Wood Log Set 3 pcs MQROCK2 Rock Set Contemporary Collection Nat...

Страница 53: ...EPLACEMENT GLASS AND BRACKETS 24G 101 Glass Panel 5 1 2 H x 9 5 8 W 24G 102 Glass Panel 5 1 2 H x 28 3 16 W 36G 101 Glass Panel 5 1 2 H x 40 3 16 W 48G 101 Glass Panel 5 1 2 H x 52 3 16 W 72G 101 Glass Panel 5 1 2 H x 76 3 16 W 96G 101 Glass Panel 5 1 2 H x 100 3 16 W 24G P202 Glass Corner Bracket c w neoprene glass mount screws 24G P205 Bottom Button Rubber base for Glass Corner Bracket 24G P202 ...

Страница 54: ...ate will be based upon the date of manufacture plus thirty 30 days Any labor material freight and or handling charges associated with any repair or replacement pursuant to this limited warranty will be your responsibility In this warranty the word installation means original installation We will not be responsible for and you the user will pay for a damages caused by accident abuse negligence misu...