Clearance Specifications
A =
2in…………. Clearances above grade, veranda, porch,
deck or balcony.
I =
3ft (USA)……..
6ft (Canada)
Clearance to service regulator
vent outlet and electric service.
B =
12in…………
36in…………
Clearances to window or door that may be
opened, or to permanently closed window.
Vinyl windows or siding.
J =
9in (USA)…….
12in (Canada)
Clearance to non-mechanical air
Supply inlet to building or the
combustion air inlet to any other
appliance.
C =
12in………… Clearance below an operable window.
K =
3ft (USA)…….
6ft (Canada)
Clearance to a mechanical air
supply inlet
D =
47in…………
60in…………
Vertical clearance to unventilated soffit or
to or to ventilated soffit located above the
fireplace.
Vinyl clad soffits.
L*=
54in………......
(See note 1)
Clearance above paved sidewalk
or a paved driveway located on
public
property.
G =
3-1/2in…….
48in………..
Clearance to inside corner.
Vinyl windows or siding.
M**= 47in………….. Clearance under veranda, porch,
deck, balcony or overhang.
H =
3ft. (Canada) Not to be installed above a gas
meter/regulator assembly within 3ft
horizontally from the center line of the
regulator.
Not allowed…. Vinyl.
NOTE: Diagrams & Illustrations not to scale.
* A fireplace shall not open directly above a sidewalk or paved
driveway which is located between two single family
dwellings and services both swellings.
**Only permitted if veranda, porch, deck or balcony is fully
open on a minimum of 2 sides beneath the floor, or if the
screened porch guidelines are followed.
Note 1
: Local codes or regulations may require different
clearances.
This appliance can be installed safely in a screened porch area
within the following guidelines:
Minimum porch area is 96sq. feet with one side fully open.
A minimum of two (2) walls can be screened, but must be open to
outside ventilation, with a minimum screen area of 64 sq. feet,
and a minimum side wall height of 78” inches.
Note
: There may be some odor and small amounts of soot associated with burning the fireplace in a screened porch. Ensuring good
cross draft ventilation and routine maintenance of the fireplace will maximize comfort and cleanliness.
6
Содержание OB24MAN
Страница 48: ...Gas Conversion for Modulator PART C 48 ...