15
Before installing Baywindow spread crushed rock
in bottom of Baywindow pan. Sprinkle Vermicelite on
top of crushed rock.
To install Baywindow assembly slightly tilt back
and hook bottom onto bottom channel of Fireplace.
Before pushing Baywindow into place check to
make sure original window is centered.
Center Baywindow and push into place,
using original screws. Compress original
window and Baywindow together.
Install top louver only.
To complete your installation place
magnet on each side as shown in
illustration and install Brass Trim.
BAY WINDOW INSTRUCTIONS MDV38 SERIES
“CAUTION”
“WARNING”
WHEN INSTALLING BAYWINDOW ASSEMBLY ORIGINAL GLASS WINDOW
MUST
REMAIN INSTALLED ON FIREPLACE. FAILURE TO FOLLOW
THESE INSTRUCTIONS MAY CAUSE INJURY.
THE BAY WINDOW IS NOT TO BE USED WITH TEMPERED GLASS MODEL MDV30 SERIES
SCREW
MAGNET
Baywindow
21.687"
ZDV3628/3630 - MDV38 FIREPLACE
Ref. No.
Part No.
Description
1
“1”
1001-500
Baywindow Assembly
1
“2”
1001-P189SI
S.I.T. Extension Hi/Low
1
“3”
1001-P188SI
S.I.T. Extension On/Off
1
“4”
Misc.
Crushed Rock
1 1/2
“5”
Misc.
Vermicelite
1
“6”
1000-309
Magnet
2
“7”
1001-506
Brass Trim Top
1
Baywindow
Crushed Rock
Vermicelite
BRASS TRIM
END