background image

 

 

 

 

 

 

Model Numbers: 

ZCV3622N, ZCV3622NE, ZCV3622NE2,  ZCV3622LP, ZCV3622LPE, ZCV3622LPE2, 

ZCVRB3622N, ZCVRB3622NE, ZCVRB3622NE2, ZCVRB3622LP, ZCVRB3622LPE, 

ZCVRB3622LPE2 

Certified to: 

ANSI Z21.88-2017 • CSA 2.33-2017 Vented Gas Fireplace Heaters, 

CSA 2.17-2017

 

 

 

 

 

Installation Instructions 

INSTALLER: Leave this manual with the appliance. 

CONSUMER: Retain this manual for future reference. 

A Division of R-Co. Inc. 

2340 Logan Ave.    

Winnipeg, Manitoba Canada 

R2R 2V3  Ph.: (204) 632-1962 

Printed in Canada November 20, 2019  

Part# 36ZCV-MAN17 

This appliance may be installed in an 

aftermarket, permanently located, 

manufactured home (USA only) or mobile 

home, where not prohibited by local codes. 

This appliance is only for use with the type 

of gas indicated on the rating plate. This 

appliance is not convertible for use with 

other gases, unless a certified kit is used.

 

ZCV3622 SOLARA 

ZCVRB3622 SKYLINE 

 

Содержание marquis SKYLINE ZCVRB3622LPE2

Страница 1: ...n this manual for future reference A Division of R Co Inc 2340 Logan Ave Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada November 20 2019 Part 36ZCV MAN17 This appliance may be inst...

Страница 2: ...ation 21 Fan Speed Control Outside of Fireplace 22 ZCV3622 ZCVRB3622 ML PRL Liner Installation Guide 23 Door and Glass Information 24 LOGC51 5 Piece Oak Log Set for ZCV3622 25 26 MQLOGC22 for MQZDV331...

Страница 3: ...And Components Horizontal Venting Table From Bottom of Fireplace 62 Venting Straight Up Through Roof 63 64 Vertical Venting over 15 Feet 65 Z47ST24 Z47ST36 Horizontal Snorkel Terminations 66 Fireplace...

Страница 4: ...e sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can...

Страница 5: ...attempting to install or remove Child Safety Screens To install screens hook bottom clip onto glass door frame then press down and push upper clip under top glass door frame then release Clip will ho...

Страница 6: ...annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and...

Страница 7: ...ication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight f...

Страница 8: ...n National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8 ga copper wire using a serrated or star washer to penetrate paint or protective coating to in...

Страница 9: ...struction contractors and finishers Frame unit with metal studs minimum 20 gauge Wooden studs may be used but may cause drywall screws to pop or pull due to wood studs drying out Minimum of 1 2 CONCRE...

Страница 10: ...r to the indoor gas fireplace being installed A Minimum sheltering cover overhang of 1 2 the distance from the base of the fireplace to the ceiling base of roofline is required EXAMPLE The bottom of t...

Страница 11: ...where the stand off locations are These stand offs are provided as indicators to illustrate the boundaries for framing Therefore no framing material is permitted to extend beyond these stand offs Vert...

Страница 12: ...Non Combustibles e g Concrete Board for Flat Wall appearance NOTE 1 2 MUST BE ADDED TO FRAMING DEPTH OF UNIT USE THIS METHOD FOR ZCVRB3622 SURROUNDS 2 Nailing Tabs are located on each side of the fire...

Страница 13: ...As a room divider B Across the corner E Flat on wall corner C As an island F Exterior wall Island installation with a top vent is possible as long as the horizontal portion of the vent system does no...

Страница 14: ...eight from bottom of fireplace 60 Top from Stand offs 0 0cm Top of 90 Bend in minimum Enclosure of 60 2 1 2 6 35cm VENTING SYSTEMS Top of Horizontal Pipe 1 1 2 3 8cm Side Bottom of Horizontal Pipe 1 2...

Страница 15: ...2 5cm All Vent Systems Vertical Vent Pipe 1 2 5cm All Vent Systems Seal rivet hole after removing rivet RESTRICTOR REMOVAL Restrictor must be removed These structures are not load bearing NOTE See Na...

Страница 16: ...lled up to edge of fireplace only NOTE MATERIALS COVERING THE FACE OF THE FIREPLACE MUST BE NON COMBUSTIBLE It is also recommended but optional to attach Non combustible facing to framing Dimensions f...

Страница 17: ...that will not combust Check your local codes and regulations to determine whether your mantel is combustible or Non Combustible The advantage to Non Combustible Mantels is that it may extend right up...

Страница 18: ...top corners Step 4 Open Lower Panel and install screws through surround Raise Lower Panel and replace screws Step 2 Slide surround over fireplace frame Step 1 Remove 2 top screws in Lower Panel and o...

Страница 19: ...wo screws Repeat for other side of fireplace 3 Install two screws into inside top of surround Replace Door Each kit contains Qty 1 Surround Frame Qty 2 Surround Side Fillers Qty 6 6 Self Tapping Screw...

Страница 20: ...Attach left and right Access Panel Brackets to inside of face frame with DT Screws Lower Face Panel will now be openable Step 2 Attach left and right Access Panel Brackets to inside of face frame with...

Страница 21: ...RNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded th...

Страница 22: ...rounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing controls Wir...

Страница 23: ...m edge over the front ledge of the firebox Then rotate the panel upright and slide it back towards the rear liner panel Make sure the top of the side panel is engaged with the top of the rear panel as...

Страница 24: ...The door can be re installed by reversing Steps 1 2 Use caution when removing broken glass wear gloves Removal of the Glass Door ZCV3622 ZCVRB3622 1 Remove the door by unlatching the 2 top latches Sim...

Страница 25: ...a Rock Sprinkle Vermiculite onto Lava Rock LOG 1 LOG 2 LOG 3 LOG 4 LOG 5 Glowing Embers Vermiculite Base Unit Lava Rock Base Unit LOG 1 LOG 2 LOG 5 LOG 3 LOG 5 LOG 4 Lava Rock Lava Rock Place Glowing...

Страница 26: ...Optional Log 4 in raised position LOG 4 26...

Страница 27: ...wing rock wool on burner as shown in step 1 being sure to leave the multiple porting areas open For Lp only the multiple porting areas can be completely covered Do not cover the Rear Porting areas wit...

Страница 28: ...n STEP 4 Place Log 4 into place as shown Do Not place directly over top of the multiple porting area on the left side STEP 5 Fill in the rest of the burner pan and ember plates with lava rock and verm...

Страница 29: ...Tube Sprinkle Vermiculite onto Lava Rock LOG 1 LOG 2 LOG 3 LOG 4 LOG 1 LOG 2 LOG 3 LOG 4 Lava Rock Lava Rock Glowing Embers Vermiculite Base Unit Lava Rock Base Unit Place Glowing Embers on sides and...

Страница 30: ...move the 2 ember plates once the grate bar is removed The 2 screws removed must be re installed once the grate bar is removed Step 3 Using the left ember plate mounting bracket slide the left ember pl...

Страница 31: ...sure that they are crossing over the single line porting MQRSP5 finished setup and burn Step 8 Place rock 3 and rock 1 into position as shown to complete the setup Lava rock and vermiculite are option...

Страница 32: ...e Apply new sealant Mill Pac Secure Lamp Plate with screws Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada Cont...

Страница 33: ...ing upward or sideways Replace burner tube and false bottom along with pilot shield STEP 4 Connect switch wires between lamp wire and transformer see schematic Connect remaining lamp wire to transform...

Страница 34: ...nition can occur The following types of glass are approved Ember Glass Material from American Fireglass Maximum amount Natural Gas is 5 lbs Propane units 5 lbs Liquid Glass from Firegear Maximum amoun...

Страница 35: ...KIT Optional Accent Lighting Kit See separate installation page NOTE Glass Media must be evenly spread over the Burner and False Bottom as described on last page before Rock Stones and Log Accessorie...

Страница 36: ...re testing of that system at test pressures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure...

Страница 37: ...rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter butt...

Страница 38: ...ition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure res...

Страница 39: ...urner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly Flame Inspection It is recommended to turn on the unit at...

Страница 40: ...012 3622 CKNG2 NG Conversion IPI 1001 P166SI 62 977 166 43 1000 P201VE 3 16 1002 P013SI 907 013 3622RB CKLP2 LP Conversion IPI 1001 P168SI 35 977 168 1 25mm 1000 P201VE 5 16 1002 P012SI 907 012 3622R...

Страница 41: ...ing parts to the new type of gas reverse all steps to reassemble burner system IMPORTANT Always check for gas leaks with a soap and water solution DO NOT USE OPEN FLAME FOR LEAK TESTING Caution The ga...

Страница 42: ...ector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sheet fo...

Страница 43: ...Gas Conversion for Modulator PART C 43...

Страница 44: ...lowing instructions supplied with conversion kit also See Parts B C 5 Adjust the primary air setting to the correct setting as specified in the manual or label plate To adjust air setting loosen screw...

Страница 45: ...dule Access Area UHS Box NOTE The gas line connection may be made of 1 2 rigid pipe or an Approved Kingsman Flex Connector such as FP15GC Since some municipalities have additional local codes it is al...

Страница 46: ...ppliance is still operable NOTE In certain instances the IPI Main Module requires resetting This can occur if the system is unable to ignite the pilot or the main burner in the allotted time period Th...

Страница 47: ...press the Thermostat Key The LCD display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or D...

Страница 48: ...or 1002 P910si Electrode Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62...

Страница 49: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 49...

Страница 50: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 50...

Страница 51: ...I or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the Remote Control Wiring Harness as per the diagrams...

Страница 52: ...Configuration 3 Remote ON OFF variable HI LO and fan capabilities Refer to the fan installation removal section for fan installation 52...

Страница 53: ...e department LIGHTING INSTRUCTIONS 1 Stop Read the above safety information on this label 2 Remove batteries from receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 T...

Страница 54: ...13 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 14 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 15 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 16 1001 P280SI TC Tubing W Fittings 1 8 2 1...

Страница 55: ...must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 Module may now be turned on off...

Страница 56: ...ON OFF and the pilot is also out follow the procedures described in this manual to light the pilot To switch from IPI to CPI Mode 1 Turn the fireplace OFF using the ON OFF Key 2 Press the Mode Key Dis...

Страница 57: ...Proflame 2 Remote Control 57...

Страница 58: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 58...

Страница 59: ...59...

Страница 60: ...u h 3 kW and 50 000 Btu h 15 kW 12 in 30 cm for appliances 50 000 Btu h 15 kW K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally L Clearance abo...

Страница 61: ...lls for wall thimble or an 8 diameter hole in a non combustible wall See Figure 2 2 For the clearance to combustible above a 90 degree bend see Clearance to Combustibles section 3 Select the approxima...

Страница 62: ...r of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use of flex pipe...

Страница 63: ...s or by using a roof pitch card Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the roof slope under the shingle...

Страница 64: ...upport configuration B Flex bend configuration C Termination mounting Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requireme...

Страница 65: ...INTAKE ADJUSTMENT PLATE NOTE Unit comes preset for short horizontal or vertical venting under a 15 feet run Follow these instructions when venting exceeds 15 foot run 1 Locate the 3 x 1 4 hex screws a...

Страница 66: ...w well is recommended with adequate and proper drainage as per local codes Leave 2 clearance below snorkel to prevent water from entering the Snorkel Termination Do not enclose the Snorkel within a wa...

Страница 67: ...ance The Intertek safety certification does not apply to this installation Before installing the appliance using this method contact the Authority Having Jurisdiction to determine if this installation...

Страница 68: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Страница 69: ...s are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer...

Страница 70: ...4 6 5 8 venting to 5 8 For Power Vent installations where flex pipe will be used up to the Power Vent unit Z47PVA Pipe Reducer 8 Sm 7 Sm Pipe Reducer 5 Sm 4 Sm Adapts PVH58 to accept 4 7 Flex Pipe On...

Страница 71: ...ITS ZCV36S1BL Surround Trim Kit for ZCV3622 Black 34 1 16 T x 39 W ZCV36LMK Lower Magnet Kit 2 Magnets 2 Access Panel Brackets 3622RB 135 Access Panel Requires ZCV36LMK Child Safety Screens IDV36CSS Z...

Страница 72: ...ecorative Glass 1 2 White MQG5A Decorative Ember Glass Cobalt Blue MQG5C Decorative Ember Glass Bronze MQG5B Decorative Ember Glass Black FIREPLACE SURROUNDS KITS ZCVRB36SBL Surround Trim Kit for ZCVR...

Страница 73: ...Switch Ivory 1451 001 1000 227 Cover Ivory 86001 001 1000 255 Orifice Brass State Size 6000 130 Explosion felt Gasket 2000 080 Thermodisc 2450 For Blower 1000 306 Thermalcord Adhesive Back for Door Fr...

Страница 74: ...Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replac...

Страница 75: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...

Отзывы: