General Vent Installation Information
This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z-Flex) Venting Kits and
components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with Montigo terminations, Duravent
(Direct Vent Pro) systems, Ameri-Vent Direct Vent Pipe systems, ICC Excel Direct systems, Metal Fab Sure-Seal DV systems, and Selkirk Direct Temp
systems.
RIGID OR HARD PIPE
When using M G Duravent, Ameri-Vent pipe, ICC Excel Direct, Metal Fab Sure-Seal DV and
or Selkirk Direct Temp a Duravent hard pipe adapter must be used (part # ZDVDFA for fire-
places and part # ZDVDKA for Stoves, Serenity and ZDV3624B). Follow installation
instructions provided by M G Duravent/Ameri-Vent/Selkirk Direct Temp, ICC Excel Direct, and
Metal Fab Sure-Seal DV for installation of pipe and adhere to the clearance to combustibles
provided in this manual. Apply a bead of Mill Pac high temp sealant to all joints of pipes,
adapters and termination, when using Kingsman Flex (Z-Flex) venting and M G Duravent
venting.
FLEX PIPE VENTING
Kingsman Flex pipe is shipped in unexpanded length. When installing pipe expand the lengths. Pipe
can be expanded to twice their lengths e.g. 4ft. to 8ft. Fully expand pipe and cut off excess.
Do not use more than 2 couplers to extend short pipes. Single sections are preferred in an
installation attaching at the fireplace and termination.
Place the spring spaces provided approximately every two feet to stabilize 4” flex in the center of 7”
flex. When forming bends place spring in bend or before and after. (See Fig. 1). Horizontal runs
require support metal straps every 2 feet. In offset installation support straps should be used to
stabilize pipe.
Expand 4” and 7” flex pipe to the point that the 7” protrudes approximately 2 to 3 inches past outer
wall and the 4” flex protrudes approximately 2 to 3 inches past the 7” flex. (See Fig. 1). Attach the
4” pipe to the termination first and secure with sealant and screws then attach the 7” flex to the
termination with caulking and screws. Termination may then be moved back to the outer wall and
attached to home screwing into the framing. Silicone around termination to waterproof. If siding
shield is going to be used attach this using same attaching hole as the top of termination after
termination has been caulked for water proofing.
Use Hi Temp Sealant
Apply a bead of Mill Pac high temp sealant to all joints and use four screws to secure each
pipe at fireplace, termination and any joint if joining any sections of pipe.
Installation of Side Wall Venting
1. To determine the minimum distance from the bottom of fireplace to center of vent
see the
Framing Your Gas Fireplace
section. Cut a hole through the wall
allowing for an 11” x 11” (inside diameter) in combustible walls for wall thimble or
an 8” diameter hole in a non-combustible wall (See Figure 2).
2. For the clearance to combustible above a 90 degree bend see
Clearance to
Combustibles
section.
3. Select the approximate vent length, precise measurements are not needed as
your flex pipe can be expanded to twice its shipped length for ease of installation
4. To install wall thimble center over 11” x 11” (inch) framing from both sides of wall
and secure. Route flex vent pipe through wall thimble (See Figure 1).
5. Before joining pipes, apply a bead of high temperature sealant (Mill Pac) to end
of pipe. First attach the four inch (4”) flue pipe to the vent termination with
sealant, and secure with the four screws provided. At this time make sure the
spacer springs are attached to the (4”) flex pipe as required. Then attach the
seven inch (7”) pipe by the same method.
6. Mount vent termination and seal to wall using caulking around the wall thimble to
weather proof. After installing the vent termination, double check to make sure
the pipe extends properly through wall thimble and into vent termination.
7. Before joining pipes to fireplace flue, apply a bead of high temperature sealant
(Mill Pac) to end of pipe. First attach the four inch (4”) flue pipe to fireplace with
sealant, and secure with the four screws provided. At this time verify that the
spacer springs are attached properly to the (4”) flex pipe as required. Then
attach the seven inch (7”) pipe by the same method.
8. Support horizontal pipes every two (2) feet (61 cm) with metal strap bands. Re-
check fireplace to make sure it is levelled and properly positioned and secured.
9. Support vertical pipes to maintain a minimum of 1” or greater clearance to
combustibles with metal strapping bands.
10. If finishing the outside wall with vinyl or wood siding it is recommended that a
Siding Shield be installed, Part Number ZDVSSLR.
Note: Vent Termination must not be recessed into wall or siding.
⚠
WARNING:
DO NOT mix parts from different systems unless stated in the manual.
FRAMING DIMENSION
Combustible Wall
Cut an 11” hole through exterior wall and frame as
shown below.
Non Combustible Wall
Cut or drill 8” or 204mm diameter hole.
NOTE: It is critical to the proper and safe operation of
this fireplace that on all connections the inner liner and
the outer casing are both caulked with liberal amounts
of sealant. Do not use any kind of tape or silicone other
than that recommended in this manu
al, Mill Pac Sealant
FLUE GAS OUTLET
MINIMUM 1” TO
COMBUSTIBLES
FIGURE 1
COMBUSTIBLE
AIR INLET
FIGURE 2
FRAMING DETAIL
THROUGH
COMBUSTIBLE WALL
THROUGH NON-
COMBUSTIBLE WALL
8” DIA
11”
11”
WARNING:
A HORIZONTAL VENT CERTIFIED
GUARD (SAFETY CAGE) IS AVAILABLE WHEN
REQUIRED BY LOCAL CODES.
MIN 54” FOR ZCV3622N/NE, LP/LPE
MIN 54” FOR ZCVRB3622N/NE, LP/LPE
MIN 54” FOR ZCV3622N/NE, LP/LPE
MIN 54” FOR ZCVRB3622N/NE, LP/LPE
LOW ENCLOSURE
FLUE RESTRICTOR REMOVED
MIN 33” FOR ZCV3622N/NE, + 12” FOR LP/LPE
MIN 33” FOR ZCVRB3622N/NE, + 12” FOR LP/LPE
LOW ENCLOSURE
FLUE RESTRICTOR REMOVED
MIN 33” FOR ZCV3622N/NE, +
12” FOR LP/LPE
MIN 33” FOR ZCVRB3622N/NE,
+ 12” FOR
LP/LPE
61
Содержание marquis SKYLINE ZCVRB3622LPE2
Страница 26: ...Optional Log 4 in raised position LOG 4 26...
Страница 43: ...Gas Conversion for Modulator PART C 43...
Страница 49: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 49...
Страница 50: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 50...
Страница 57: ...Proflame 2 Remote Control 57...
Страница 59: ...59...